DE-05-04-1 - Field Performance of a Zoned Forced-Air Cooling System in an Energy-Efficient Home PDF

DE-05-04-1 - Field Performance of a Zoned Forced-Air Cooling System in an Energy-Efficient Home PDF

Name:
DE-05-04-1 - Field Performance of a Zoned Forced-Air Cooling System in an Energy-Efficient Home PDF

Published Date:
2005

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The objective of the current investigation was to evaluate the field performance of a forced-air cooling system in an energy-efficient home. The test site was a three-story home in Pittsburgh, Pennsylvania, and field measurements were made during the cooling season. The forced-air system was zoned by floor and operated in both a zoned mode and in a non-zoned mode. The system performance was evaluated based on air temperature measurements and space conditioning energy use. The room air temperatures were compared to the requirements of ASHRAE Standard 55 (ASHRAE 2004b) for thermal comfort and recommendations of ACCA Manual D (ACCA 1995) for uniform temperatures between rooms. In non-zoned mode, the temperatures on the second and third floors exceeded the setpoint. Zoned operation improved the system temperature control performance, providing temperatures on the first and third floors that satisfied the ASHRAE and ACCA requirements. Temperature control for the second floor was not acceptable because of three problems: false thermostat temperatures due to air leakage, heat gain to uninsulated supply ducts in partially conditioned attic space, and solar load diversity. The zoning control increased the energy use per cooling degree-hour by approximately 6%; however, this was not considered to be a significant variation due to the limited evaluation period. One conclusion of the study is that heat gain to ducts in conditioned (or partially conditioned) space can significantly impact the delivered cooling capacity to rooms. A preliminary conclusion from the investigation is that a zoned forced-air system can provide acceptable temperature control during cooling operation in an energy-efficient home. Additional research is recommended to investigate the impact of correcting the problems associated with Zone 2 (thermostat temperature issue and ducts in the attic space).

Units: Dual


File Size : 1 file , 4.6 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-26954
Published : 2005

History


Related products


Best-Selling Products

AFGS AFGS-87219B
Published Date: 10/23/2012
Electrical Power Systems, Aircraft
$7.2
AFGS AFGS-87241A Notice 2 - Cancellation
Published Date: 05/15/2014
Simulators, Flight (No S/S Document)
$3.6
AFGS AFGS-87249 Notice 4 - Cancellation
Published Date: 10/28/2012
Mechanical Equipment and Subsystems, Requirements for the Integrity of (S/S by MIL-STD-1798)
$3.6
AFGS AFGS-87271A Notice 1 - Validation
Published Date: 04/24/2013
Engines, Unmanned Air Vehicle, Airbreathing Gas Turbine, Expendable
$3.6