DE-13-036 -- Energy Implications of In-line Filtration in California Homes PDF

DE-13-036 -- Energy Implications of In-line Filtration in California Homes PDF

Name:
DE-13-036 -- Energy Implications of In-line Filtration in California Homes PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Furnace energy use and filter pressure drop was measured for forced-air heating/cooling systems in ten California homes. Each home was monitored for at least one year. Measurements were made of the blower energy, filter pressure drop, supply and return plenum pressures, and temperatures, as well as the indoor temperature. At least two filter types were installed, including a MERV 16 filter, in most houses. As the filter became dirty, in some homes the blower energy use increased, and in others the blower energy use decreased. Increasing blower energy use was associated with BPM blower motors, and decreasing blower energy was associated with PSC blower motors. There was a large pressure drop across the MERV 16 filter as compared to the lower-MERV filters. Many homeowners complained of noise because of the large pressure drop and air bypassing the filter. In addition to field measurements, simulations were made for a typical new home in six California climate zones, with combinations ofPSCandBPMblowers, and low and high duct leakage. The results indicate that for MERV 10–13 filters, as compared to a baseline of MERV 5, the effects on blower energy use are moderate (less than 5%) over a wide range of performance conditions and climates. Using MERV 16 filters leads to problems in terms of noise, usability, and potential for significantly increased blower energy use (about 20%). In systems that are already close to blower performance limits with low- MERV filters, the addition of a MERV 16 filter pushed the blowers to their performance limits. The effect of filter loading on total HVAC system energy performance was small (less than 1%) for most homes. However, with high filter loading rates for MERV 16 filters, the performance deteriorated significantly (up to 20% increases in energy use for a system with a leaky duct and a BPM blower) indicating that a filter loading indicator should be required for MERV 16 filters.


File Size : 1 file , 5.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 19
Product Code(s) : D-DE-13-036
Published : 2013

History


Related products


Best-Selling Products

ANSI/ANSLG C78.21-2003
Published Date:
American National Standard for Electric Lamps - PAR and R Shapes
$66.9
ANSI/ANSLG C78.357-2010
Published Date: 02/15/2011
For incandescent lamps: Tungsten Halogen Lamps (non-vehicle)
$81.6
ANSI/ANSLG C78.377-2011
Published Date: 10/06/2011
American National Standard for Specifications for the Chromaticity of Solid State Lighting (SSL) Products
$33.9
ANSI/ANSLG C78.380-2002
Published Date: 2002
High Intensity Discharge Lamps - Method of Designation
$26.4
ANSI/ANSLG C78.380-2007
Published Date: 2007
American National Standard for Electric Lamps - High-Intensity Discharge (HID) - Method of Designation
$26.4
ANSI/ANSLG C78.40-1992 (R2003)
Published Date:
American National Standard for Mercury Lamps - Specifications
$70.8