DE-13-C006 -- Short Term Notification Demand Response Measures in Office Buildings in a Hot and Dry Climate PDF

DE-13-C006 -- Short Term Notification Demand Response Measures in Office Buildings in a Hot and Dry Climate PDF

Name:
DE-13-C006 -- Short Term Notification Demand Response Measures in Office Buildings in a Hot and Dry Climate PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Demand response (DR) is a load curtailment strategy strongly advocated by electric utilities nationwide to tide over periods when grid usage is likely to reach/exceed its maximum capacity. It essentially involves notifying commercial customers in advance and incentivizing them to reduce their consumption voluntarily during such peak periods. In essence, this notification can be either short term with a lead time of 2-3 hrs, or long term (12-24 hour notification). The demand-side curtailment measures which a customer can implement under the former are fewer and, often, not transparent. In this paper, we present the results of a simulation study which investigated the effect of various short notification DR measures and their resulting impact on indoor occupant comfort. Two Department of Energy (DOE) prototype commercial buildings, a medium size office building (53,600 sq. ft. or 5,000 m2) and a large size office building (498,600 sq. ft. or 46,300 m2) were simulated under the hot and dry climate of Phoenix, AZ using the detailed building energy simulation program, EnergyPlus V6.0.0. The peak diurnal period selected was 12:00-18:00 hours (6 hour window). Analysis of the weather file led us to select two hot peak days, one reflective of the summer high-peak (15th July) and another of the mid-peak (29th June). The impact of building thermal mass as well as several other measures such as reducing lighting levels, increasing thermostat set points, adjusting supply air temperature, resetting chilled water temperature was studied. Subsequently the simulation results were distilled and summarized in tabular form according to the different combinations of curtailment measures needed to achieve different levels of DR reductions along with the associated percentage of people dissatisfied (PPD). The approach described in this paper is likely to be better adopted by building owners and utility operators contemplating DR response since it allows them to evaluate alternative sets of measures and their occupant comfort consequences for different magnitudes of load reduction. This methodology can be extended to other buildings and climates.


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-DE-13-C006
Published : 2013

History


Related products


Best-Selling Products

CAN/ULC 554-05 (R2010)
Published Date: 10/04/2011
Standard for Water Based Agent Fire Extinguishers, Including Amendment 1
CAN/ULC 60832-09
Published Date: 04/09/2009
Insulating poles (Insulating Sticks) and Universal Tool Attachments (Fitting) for Live Working
CAN/ULC 60895-09 Draft
Published Date: 01/01/2009
Live Working - Conductive Clothing For Use at Nominal Voltage Up to 800 kV A.C. and ?600 kV D.C.
CAN/ULC 60903-09
Published Date:
Live Working - Gloves of Insulating Material
CAN/ULC 61243-3-10
Published Date: 12/01/2010
Live working -- Voltage Detectors -- Part 3: Two-Pole Low-Voltage Type
CAN/ULC 61477-05
Published Date: 01/01/2006
Live Working - Minimum Requirements for the Utilization of Tools, Devices and Equipment (CEI/IEC 61477:2001+A1:2002, IDT)