DE-13-C019 -- Role of HVAC System Configuration on Probable Flow Path of Airborne Pathogens in a Patient Room PDF

DE-13-C019 -- Role of HVAC System Configuration on Probable Flow Path of Airborne Pathogens in a Patient Room PDF

Name:
DE-13-C019 -- Role of HVAC System Configuration on Probable Flow Path of Airborne Pathogens in a Patient Room PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The distribution of supply air determines the resulting air velocities, temperatures, and concentration of contaminants in a patient room. This inturn determines thermal comfort and potential for transmission of airborne infectious pathogens in a patient room. Several interrelated factors canaffect the performance of air distribution systems including the location and type of supply air diffusers, location and size of return air grills, andlocation and strength of various heat sources.

This paper with the help of Computational Fluid Dynamics (CFD) analyses describes the impact of various locations of supply air diffusers and return air grill on the airflow patterns, temperature distribution, resulting thermal comfort of occupants, and on the probable flow path of airborne pathogens in a patient room. These analyses indicate linear diffusers can cause strong recirculation and entrainment (induction) flows in the room. Depending on the location of the return grill the airborne pathogens released from the patient's face can get entrained back into the supply air stream and can eventually spread into the entire room. Placing the return grill behind the linear supply diffuser over the patient's head showed most promising results in reducing the entrainment of airborne pathogens back into the supply stream. It is noted that CFD can be an effective tool for analyzing and optimizing the design of air distribution systems to obtain the desired combination of occupant thermal comfort and the best possible hygienic conditions in patient rooms.


File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-DE-13-C019
Published : 2013

History


Related products


Best-Selling Products

DOXPUB 02-0001-SOP
Published Date: 08/01/2007
Recovery of Cryopreserved Cells
DOXPUB 02-0002-SOP
Published Date: 08/01/2007
Removal of Adherent Cells from Tissue Culture Flasks Using Trypsin/EDTA Solution
$4.2
DOXPUB 02-0003-SOP
Published Date: 08/01/2007
Assembly, Standardization, Sterilization and Inoculation of the Cell-Pharm Hollow Fiber Bioreactor for Antibody Production
$20.7
DOXPUB 02-0006-SOP-1.0
Published Date: 11/01/2004
Concentration of Bulk Antibody
$60
DOXPUB 02-0006-SOP
Published Date: 08/01/2007
Concentration of Bulk Antibody
$14.7
DOXPUB 02-0007-SOP
Published Date: 08/01/2007
Cell Culture Fluid Waste Disposal
$5.7