DE-13-C035 -- Inverse Determination of Air Supply Speed for Room Ventilation Based on Reduced Order Models PDF

DE-13-C035 -- Inverse Determination of Air Supply Speed for Room Ventilation Based on Reduced Order Models PDF

Name:
DE-13-C035 -- Inverse Determination of Air Supply Speed for Room Ventilation Based on Reduced Order Models PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

To select proper diffusers or air terminal devices for room ventilation, air supply momentum at the devices must be determined. Given a required ventilation rate, the selected air supply speed should assure good ventilation performance and appropriate local velocities near an occupant. However, varying of local air velocities with respect to the air supply momentum is nonlinear. Conventional method to determine the air supply flow intensity has to use an iterative guess-and-correction procedure. This investigation proposes a model for designers to quickly determine the air speed at an air supply device. The cause-effect relation between the air supply momentum and the resulted local velocities in the occupied zone is cast into reduced order flow models. By proper orthogonal decomposition of the incompressible Navier-Stokes equations and performing the Galerkin projection, reduced order models (ROMs) for flow motion are derived. The control function method is applied to generate new spatial modes of the ROMs during optimization. Because this investigation focuses on development of ROMs, no systematic optimization algorithm is utilized. The optimal air supply speed is obtained by enumerating different air speeds and then picking up the one that leads to the minimum objective function. To test the proposed ROMs, the above procedure was implemented to solve for the air supply speed in a two-dimensional ventilation enclosure. By specifying the target velocity distribution on the mid horizontal line, the ROMs are found being able to correctly and quickly provide the required air supply speed at the air supply slot opening.


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-DE-13-C035
Published : 2013

History


Related products


Best-Selling Products

HI/HYDRON 001
Published Date:
I=B=R Guide-Residential Hydronic Heating Installation/Design
HI/HYDRON 003
Published Date: 01/01/1993
S-40 Snow Melting Calculation and Installation
HI/HYDRON 004
Published Date: 01/01/1995
Radiant Floor Heating
HI/HYDRON 005
Published Date: 01/01/2008
I=B=R Ratings for Boilers, Baseboard Radiation, Finned Tube (Commercial) and Indirect-Fired Water Heaters
HI/HYDRON 006
Published Date: 01/01/2007
BTS-2000-Testing Standard for Commercial Space Heating Boilers
HI/HYDRON 007
Published Date: 01/01/2008
I=B=R Rating Procedure for Residential and Commercial Boilers