DE-93-16-1 -- A Computer Analysis of Moisture Accumulation in the Walls of Manufactured Housing PDF

DE-93-16-1 -- A Computer Analysis of Moisture Accumulation in the Walls of Manufactured Housing PDF

Name:
DE-93-16-1 -- A Computer Analysis of Moisture Accumulation in the Walls of Manufactured Housing PDF

Published Date:
1993

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A detailed computer analysis was conducted to investigate the effectiveness of three alternative practices for controlling moisture accumulation in the walls of manufactured housing during the winter. The three practices included (1) providing an interior vapour retarder, (2) using permeable sheathing and siding, and (3) providing an outdoor ventilated cavity. The current HUD Manufactured Home Construction and Safety Standards do not require a vapour retarder for practices 2 and 3. The analysis was carried out for cold winter climate (Madison, WI), an intermediate winter climate (Boston, MA), a mild winter climate (Atlanta, GA), and a Pacific Northwest climate (Portland, OR). The practice of providing a vapour retarder was found to be effective in all four climates. The moisture content of the siding was always considerably below fibre saturation. On the other hand, the practice of using permeable sheathing and siding and the practice of providing an outdoor ventilated cavity were not always effective in colder climates. Moisture accumulated above fibre saturation, and free liquid water existed within the pore structure, providing a potential for material degradation. A detailed computer analysis was also conducted of moisture accumulation in manufactured housing walls in a hot and humid climate (Lake Charles, LA). During the summer, moisture from the outdoor environment is transferred into manufactured housing by diffusion and, more important, infiltration. As a result, moisture accumulates at interior layers of the construction cooled by air conditioning. When an interior vapour retarder is used in the construction, the relative humidity at the outside surface of the vapour retarder can approach saturation, thereby providing an environment conducive to mould and mildew growth.

KEYWORDS: computers, calculating, moisture, walls, housing, prefabricated construction, winter, vapour barriers, content, relative humidity, moulds.


File Size : 1 file , 1.6 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17549
Published : 1993

History


Related products


Best-Selling Products

UNE-IEC/TR 60865-2:2006 IN
Published Date: 04/26/2006
Short-circuit currents - Calculation of effects - Part 2: Examples of calculation.
UNE-IEC/TR 60893-4:2005
Published Date: 02/09/2005
Insulating materials - Industrial rigid laminated sheets based on thermosetting resins for electrical purposes - Part 4: Typical values
UNE-IEC/TR 60909-2:2010 IN
Published Date: 02/17/2010
Short-circuit currents in three-phase a.c. systems - Part 2: Data of electrical equipment for short-circuit current calculations.
UNE-IEC/TR 61000-2-8:2006 IN
Published Date: 06/28/2006
Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results (IEC/TR 61000-2-8:2002)
UNE-IEC/TR 61000-3-6:2006 IN
Published Date: 07/19/2006
Electromagnetic compatibility (EMC) - Part 3: Limits - Section 6: Assessment of emission limits for distorting loads in MV and HV power systems - Basic EMC publication (IEC/TR 61000-3-6:1996)
UNE-IEC/TR 61010-3:2006 IN
Published Date: 03/15/2006
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3: Protocol for the preparation of conformity verification reports for the IEC 61010 2nd edition series .