Designing Sustainable Single-ply Membrane Roof Systems for Hot Climates PDF

Designing Sustainable Single-ply Membrane Roof Systems for Hot Climates PDF

Name:
Designing Sustainable Single-ply Membrane Roof Systems for Hot Climates PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The growing popularity of increased thermal insulation, in association with code and standard mandates, assists in mitigating exterior ambient temperatures and heat flow migration influences on building interior environments. Some have tried to mitigate these exterior influences on the interior by roof surface color alone; an incorrect precept. Roof color alone, a single roof system component, cannot mitigate exterior influence in and by itself. Insulation, roof system design, roof deck, etc. all have a role to play. HVAC designers have not been informed as to how roof system design can detrimentally affect HVAC performance: Increased air temperatures above the roof surface, high temperature heating of roof top piping, and the heating of roof top units by reflection of roof surface have all resulted in HVAC performance well below that which it was designed, expected, or anticipated for. Appropriate roof system design is the result of the architect, engineer and building owner working together, taking into consideration building use and the effects of the climatic and environmental conditions expected to be experienced. This paper will draw on the author's 30 year history of roof system design and forensic observations to review and explain the effects of roof system design on HVAC design in hot climates, from the perspective of a roof system design. Concerns such as heat flow, reflected ultraviolet light effects, roof top temperatures and their potential detrimental effects on HVAC performance will be reviewed. Additionally, design recommendations and detailing suggestions for achieving long-term roof service life performance in hot climates will be reviewed. Proactive design recommendations for HVAC designers on how to deal with roof borne effects will also be provided.


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-2014FICEConf-13-4
Published : 2014

History


Related products


Best-Selling Products

AENOR EA 0007
Published Date: 09/07/2016
Requisitos del sistema de seguimiento y agregación de los precios del papel para reciclar.
$12.9
AENOR EA 0014
Published Date: 02/14/2003
Marcado por impresión de los elementos calefactores que utilizan cable calefactor según la Norma UNE 21155-1.
$5.4
AENOR EA 0032
Published Date: 07/11/2007
Equipos estabilizadores de tensión y reductores de flujo luminoso en cabecera de línea. Requisitos generales y de seguridad
$23.7
AENOR EA 0039
Published Date: 02/04/2009
Cables multiconductores de tensión asignada 0,6/1 kV no propagadores del incendio, aislados con polietileno reticulado y con cubierta de poliolefina, para utilizar como instalación fija en circuitos de control.
$18.9
AENOR EA 0042
Published Date: 12/23/2014
Aparamenta de baja tensión. Equipos auxiliares. Conjuntos de bloques de conexión para la verificación de contadores de energía.
$22.2
AENOR EA 0051
Published Date: 12/23/2014
Cables eléctricos de distribución con aislamiento extruido, de tensión asignada desde 3,6/6 (7,2) kV hasta 20,8/36 (42) kV inclusive. Cables unipolares y unipolares reunidos con aislamiento de HPTE. Cables con cubierta de compuesto de poliolefina (tipo 1, tipo 2 y tipo 3)
$22.2