Drying Rate of Timber-Framed External Wall Assemblies in Nordic Climate PDF

Drying Rate of Timber-Framed External Wall Assemblies in Nordic Climate PDF

Name:
Drying Rate of Timber-Framed External Wall Assemblies in Nordic Climate PDF

Published Date:
2004

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This research looks into the moisture behavior of timber-framed external wall assemblies under Nordic climate conditions. The focus of this study was to measure drying rates of wall assemblies and to study the effects of different material layers on drying times from the viewpoint of water vapor diffusion of moisture-permeable walls (walls with an air barrier and no vapor barrier) and moisture-impermeable walls (walls with air and vapor barrier). Drying times have been estimated from laboratory test results. Laboratory tests were done with test equipment that allowed full-scale laboratory tests in real climate conditions. The main focus has been on relative humidity and temperature changes in the outer surface of the insulation layer (behind the sheathing) in different climatic conditions. Analysis was based on three criteria: limit value of mold growth during the autumn period, condensation during the winter period, and drying times during the spring period. It was noticed that water vapor resistance of the inner lining of the wall assembly has no significant effect on drying times during the spring period. In other words, moisture-permeable and impermeable walls have the same drying times if their other properties are identical. It can be generally noted that the water vapor resistance ratio between the inner and outer lining should be at least 5:1 in a Finnish climate. However, there are a lot of different variables that have an effect on this ratio (conditions of outdoor air, humidity excess of indoor air, physical properties of materials, etc.) and, therefore, in some cases, this ratio should be bigger.

 


File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-BldgsIX79
Published : 2004

History


Related products


Best-Selling Products

PDI BPSGI
Published Date:
Basic Principles for Sizing Grease Interceptors
PDI G 101
Published Date: 03/01/2010
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance
PDI G 102
Published Date:
Testing and Certification for Grease Interceptors with FOG Sensing and Alarm Devices
PDI GGI-EM
Published Date: 01/01/2010
Guide To Grease Interceptors: Eliminating the Mystery
PDI MGO
Published Date:
Model Grease Ordinance
PDI MSREPFS
Published Date: 01/01/2009
MINIMUMSPACE REQUIREMENTS FOR ENCLOSED PLUMBING FIXTURE SUPPORTS