Pollutant removal by forced ventilation in energy efficient buildings is one of the most applied strategies to ensure sufficient quality of indoor air. Dispersion of aerosol particles in rooms emitted from daily activities of inhabitants highly depends on air distribution method, ventilation effectiveness and air change rate. The aim of the study was to outline the trends of particle movement in rooms in relation to air change rate as well as air distribution method. Higher ventilation effectiveness is considered to be one of the energy conservation measures as lower air change rates may be sufficient to ensure particle removal from the ventilated rooms.

Experiments were carried out in the full scale test chamber. Displacement ventilation and two types of mixing ventilation with one-way as well as four-way air supply through ceiling diffusers were selected for the study. Air change rates of 3 and 4 times per hour were selected for the experiments. Aerosol injection pulse was generated using a solution of sodium chloride. Concentration of particles was monitored within 10 minutes after the injection using six optical particle counters located in one plane section of the room using the time step of 1 second.

Results of the experiment outline trends of particle movement in rooms ventilated by means of mixing and displacement ventilation. The mixing ventilation with one-way air supply at both ventilation rates of 3 and 4 ach prevented aerosol particle transport to the opposite side of the room. The mixing ventilation with four-way air supply performed significantly better at 4 ach compared to 3 ach and the removal of particles from the chamber was rather slow in case of displacement air distribution.

The results provide indication that the optimization of air distribution methods may be viable technology for air quality management in energy efficient buildings.


File Size : 1 file , 1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 6
Product Code(s) : D-2013IAQConf-35
Published : 2013

History


Related products


Best-Selling Products

UNE-ISO/TR 10017:2004
Published Date: 06/25/2004
Guidance on statistical techniques for ISO 9001:2000
UNE-ISO/TR 12343:2010 IN
Published Date: 01/27/2010
Road vehicles -- Symbols for electrotechnical diagrams
UNE-ISO/TR 12885:2010 IN
Published Date: 11/24/2010
Nanotechnologies. Health and safety practices in occupational settings relevant to nanotechnologies
UNE-ISO/TR 14062:2007 IN
Published Date: 12/27/2007
Environmental management. Integrating environmental aspects into product design and development. (ISO/TR 14062:2002)
UNE-ISO/TR 15801:2008 IN
Published Date: 10/08/2008
Electronic imaging -- Information stored electronically -- Recommendations for trustworthiness and reliability
UNE-ISO/TR 15916:2007 IN
Published Date: 04/25/2007
Basic considerations for the safety of hydrogen systems. (ISO/TR 15916:2004)