Effects of Ventilation and Air Cleaning on Indoor Air Quality of An Indoor Swimming Pool - Mass Balance Analysis Approach PDF

Effects of Ventilation and Air Cleaning on Indoor Air Quality of An Indoor Swimming Pool - Mass Balance Analysis Approach PDF

Name:
Effects of Ventilation and Air Cleaning on Indoor Air Quality of An Indoor Swimming Pool - Mass Balance Analysis Approach PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Major air contaminants of concern in indoor swimming pools are vaporized disinfection byproducts (DBPs) formed in the swimming pool water. Conventionally we rely on ventilation to control indoor air contaminant levels. ASHRAE Standard 62.1 Ventilation for Acceptable Indoor Air Quality (2010) specifies the required minimum outdoor air ventilation rate for indoor swimming pools in Ventilation Rate Procedure (VRP). However, swimming pools compliant to the required ventilation rate can still face unacceptable airborne DBP levels. In order to improve the indoor air quality (IAQ) in swimming pools, the World Health Organization (WHO) and US Center for Disease Control (CDC) recommend much higher outdoor air ventilation rate than ASHRAE Standard 62.1.

Under the presence of strong sources of specific air contaminants like swimming pools, air cleaning can be a promising technique to improve IAQ. ASHRAE Standard 62.1 Indoor air Quality Procedure (IAQP) allows a reduced outdoor air ventilation rate when it is combined with air cleaning. This paper presents brief review on ventilation requirement by standard and guidelines for indoor swimming pools, and the results of mass balance analysis carried out to investigate the effects of ventilation and air cleaning on the indoor air pollution levels in a typical public swimming pool. Ventilation rates given by ASHRAE Standard 62.1 VRP as well as those by other guidelines were considered and compared with ASHRAE Standard 62.1 IAQP, which has the lowest ventilation rate in combination with air cleaning.


File Size : 1 file , 510 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-CCC12-19
Published : 2012

History


Related products


Best-Selling Products

CI/CHLOR IB/A
Published Date: 05/01/2023
Instruction Booklet: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100-LB. & 150-LB. CHLORINE CYLINDERS
CI/CHLOR IB/A
Published Date: 07/01/2014
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100 LB. & 150 LB. CHLORINE CYLINDERS
CI/CHLOR IB/A
Published Date: 01/01/2021
Instruction Booklet: Chlorine Institute Emergency Kit "A" For 100LB. & 150 LB. Chlorine Cylinders
$12
CI/CHLOR IB/A
Published Date: 01/01/2013
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100 LB. & 150 LB. CHLORINE CYLINDERS
CI/CHLOR IB/B
Published Date: 12/01/2013
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “B” FOR CHLORINE TON CONTAINERS
CI/CHLOR IB/B
Published Date: 07/01/2014
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “B” FOR CHLORINE TON CONTAINERS