Energy Savings for Stucco Walls Coated with Cool Colors PDF

Energy Savings for Stucco Walls Coated with Cool Colors PDF

Name:
Energy Savings for Stucco Walls Coated with Cool Colors PDF

Published Date:
2008

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Solar radiation control is an effective means to decrease energy needs for cooling. Cool colors, with the same appearance as standard colors but higher solar reflectance in the infrared, are of interest for walls. Walls can be coated for possible energy savings without disturbing the existing structure. However, solar radiation control cannot be as effective on walls as it is on roofs because walls do not receive maximum solar load during the peak cooling season. In order to quantify potential energy savings, field tests were done on adjacent walls coated with and without cool colors. Data from a year of tests in Oak Ridge, TN were used to validate a DOE 2.2 model of a south-facing wall. A model for a single-story residence was configured with stucco-coated wood-framed and concrete masonry unit (CMU) exterior walls. It was exercised in cooling and mixed climates. Annual cooling energy savings for use of a cool color (solar reflectance of 0.495) instead of a standard coating with the same color (solar reflectance of 0.238) were 4% to 13% (4% to 9% in the cooling climates). Whole house peak cooling load savings due to the cool walls averaged 3% to 4%. The annual heating energy penalties for cool walls compared to conventional walls were 4% to 24% (4% to 10% in the mixed climates). They exceeded cooling energy savings for moderate heating needs. If annual energy savings are the sole criterion for application of cool colors on the walls of the modeled residence, 65°F heating degree-days (18°C heating degree-days) should be less than about 2800 (1560) for CMU walls or about 3300 (1830) for wood-framed walls. Atlanta has 3090 (1720) heating degree-days.

Presented at Thermal Performance of Exterior Envelopes of Whole Buildings X – December 2007

Units: Dual


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-BldgsX20
Published : 2008

History


Related products


Best-Selling Products

SAA/SNZ HB 104:1997
Published Date: 01/01/1997
A guide to year 2000 compliance
$28.116
SAA/SNZ HB 76:2010
Published Date: 08/19/2010
Dangerous Goods - Initial Emergency Response Guide
$20.196
SAA/SNZ HB1:1994
Published Date: 10/17/1994
TECHNICAL DRAWING for students
$8.712
SAA/SNZ HB18.43.1:1998
Published Date: 09/05/1998
Guidelines for third-party certification and accreditation Guide 43 - Proficiency testing by interlaboratory comparisons, Part 1: Development and operation of proficiency testing schemes
$4.95
SAA/SNZ HB18.43.2:1998
Published Date: 09/05/1998
Guidelines for third-party certification and accreditation - Guide 43 - Proficiency testing by interlaboratory comparisons, Part 2: Selection and use of proficiency testing schemes by laboratory accreditation bodies
$2.376
SAA/SNZ HB18.58:1993
Published Date: 01/01/1993
Guideline for third-party certification and accreditation, Part 58: Calibration and testing laboratory accreditation systems - General requirements for operation and recognition
$2.376