HI-85-02-2 -- Heat Transfer from Earth-Coupled Heat Exchangers — Experimental and Analytical Results PDF

HI-85-02-2 -- Heat Transfer from Earth-Coupled Heat Exchangers — Experimental and Analytical Results PDF

Name:
HI-85-02-2 -- Heat Transfer from Earth-Coupled Heat Exchangers — Experimental and Analytical Results PDF

Published Date:
1984

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Experimental heat transfer results obtained with tubular heat transfer coils buried in soil are presented along with a finite difference simulation model that predicts the heat transfer to or from the buried pipes and the temperature distribution in the soil surrounding the buried pipes. The results were obtained with two different earth-coupled coils. Each coil was fabricated from 2.2 in. (5.6 cm) ID nominal 2 in. diameter cast iron pipe. The length of the heat exchanger for each earth-coupled system was 90 ft. (27.4 m). The earth-coupled coils were buried at a depth of 2.75 ft. (0.84 m) below the surface of the earth.

The experimental data cover a time span of seven months and represent operation of the earth-coupled coils at various heat rates. Some of the prime quantities measured on a continuous basis are the earth's temperature at several locations in the vicinity of the buried coils, the far earth temperature, the solar insolation, moisture content of the soil, and the heat transferred to or from the buried coils to the surrounding soil. The finite difference model tracks the temperature distribution in the earth surrounding the coils on a continuous basis and predicts the earth's temperature at many locations adjacent to the earth-coupled coil with a maximum error of 4 F (2 .2 °C) during the seven month test. As parameters, the finite difference model included the moisture content of soil, convection at the surface of the earth, emissivity of the soil, radiation exchange at the air- soil interface, as well as all of the pertinent parameters related to the flow of the heat transfer fluid through the buried pipes. The results presented, both experimental and simulated, have direct application in the design of earth-coupled water-source heat pump systems.

Units: Dual

 


File Size : 1 file , 910 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-HI-85-02-2
Published : 1984

History


Related products


Best-Selling Products

SN-ISO/TS 10993-19:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-19:2020
Published Date: 12/14/2020
Biological evaluation of medical devices — Part 19: Physico-chemical, morphological and topographical characterization of materials
SN-ISO/TS 10993-20:2006
Published Date: 07/01/2014
Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices
SN-ISO/TS 14067:2013
Published Date: 07/01/2013
Greenhouse gases — Carbon footprint of products — Requirements and guidelines for quantification and communication
SN-ISO/TS 14092:2020
Published Date: 09/02/2021
Adaptation to climate change - Requirements and guidance on adaptation planning for local governments and communities
SN-ISO/TS 14812:2022
Published Date: 09/20/2023
Intelligent transport systems - Vocabulary