HO-18-C007 -- The Effect of Fenestration System on Building Daylighting and Solar Radiation: An Experimental Study in Humid Subtropical Climate PDF

HO-18-C007 -- The Effect of Fenestration System on Building Daylighting and Solar Radiation: An Experimental Study in Humid Subtropical Climate PDF

Name:
HO-18-C007 -- The Effect of Fenestration System on Building Daylighting and Solar Radiation: An Experimental Study in Humid Subtropical Climate PDF

Published Date:
2018

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Modern buildings tend to have large glass facades for good outdoor view and daylight utilization. Compared to traditional masonry wall construction, the lower thermal resistance values can result in increased heat losses (and solar gains) and hence reduce the heating and cooling energy efficiency of modern transparent facades. The balance between daylighting benefits and energy requirements should be investigated in detail for optimizing the design of modern fenestration systems by local climate.

This experiment studies the effects of window orientation, size, and glazing properties (low-e) on Useful Daylight Illuminance (UDI) and Transmitted Solar Radiation (ESR). Unlike other experimental studies, the window properties are varied without replacing the window installation – thus controlling construction-related sources of error. Window properties were instead varied by rotating the wheel-mounted test house to a different orientation and using opaque polystyrene foam to change the effective window size. Two test houses (1.8 x 1.8 x 2.4 m) were placed outdoors in a hot and humid climate of southeastern Texas. The test houses' windows had different low-emissivity glazings (visible transmittances of 74% and 64%). Seven combinations of window orientation (facing North, West, East, or South) and window size (16%, 25%, 36%, or 47% Window-To-Wall Ratio (WWR)) were tested for each test house. Solar radiation, light, and temperature were monitored inside and outside of the test houses every 5 minutes for several days per setting. Daily UDI at workplane height (0.8 m) and daily ESR through the window were calculated and compared to determine optimal orientation-size settings. As expected for the sunny climate, glare (over 2000 lux) was the main source of non-useful daylight. Adding shade controls on east and west orientations will reduce ESR and glare in the mornings and afternoons, respectively. South orientation should be protected by a shallow roof overhang at this latitude during summer months. These preliminary results suggest the best size-orientation combination tested was a 16% WWR window in the south orientation, which achieved a 99% average UDI for both window glazing types. These results were attributed to the sun angle and the proportion of direct and reflected sunlight. Global horizontal solar radiation, sol-air temperature, and clearness index (Kt) were calculated to control for weather variations and to improve comparisons for limited data.


File Size : 1 file , 510 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-HO-18-C007
Published : 2018
Units of Measure : Dual

History


Related products


Best-Selling Products

ISEA 101-1996 (R2008)
Published Date: 01/06/1997
Limited-Use and Disposable Coveralls - Size and Labeling Requirements
$3
ISEA 101-2014
Published Date: 07/08/2014
American National Standard for Limited-Use and Disposable Coveralls -- Size and Labeling Requirements
$3
ISEA 102-1990 (R2009)
Published Date: 05/25/1990
American National Standard for Gas Detector Tube Units - Short Term Type for Toxic Gases and Vapors in Working Environments
$3
ISEA 103-2010 Erratum (2011)
Published Date: 09/07/2011
Erratum to American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
Free Download
ISEA 103-2010
Published Date: 09/29/2010
American National Standard for Classification and Performance Requirements for Chemical Protective Clothing
$15.9
ISEA 104-1998 (R2009)
Published Date: 07/13/1998
Air Sampling Devices - Diffusive Type for Toxic Gases and Vapors in Working Environments
$3