Hygrothermal Performance of Masonry Cavity Walls with Very Low U-Factor: A Test House Evaluation PDF

Hygrothermal Performance of Masonry Cavity Walls with Very Low U-Factor: A Test House Evaluation PDF

Name:
Hygrothermal Performance of Masonry Cavity Walls with Very Low U-Factor: A Test House Evaluation PDF

Published Date:
2001

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The Kyoto agreement obliges the industrialized world to increase investments in energy efficiency. As building usage generates 35% to 40% of the total annual energy consumption, the construction of Low Energy and Low Pollution (L2EP) buildings and L2EP retrofits should rank high on the list of priorities. L2EP presumes a well-insulated building enclosure with opaque whole wall U-factors close to 0.2 W/(m2 -K). That U = 0.2 W/(m2 -K) requirement will alter the design of the traditional masonry cavity wall in Western Europe quite drastically. To gain a better view of the criteria to be set, a test house campaign on six pairs of 1.8 m wide and 2.7 m high masonry cavity walls with U = 0.2 W/(m2 -K) as an intended U-value was initiated. For each pair, one wall faced southwest, the other northeast. The walls differed in terms of capillary properties of the brick veneer, the application of a full or a partial cavity fill, the use of fiberglass or extruded polystyrene as a filling material, the level of workmanship, and the air permeability of the inside leaf. During two years, temperature gradients, relative humidity profiles, heat flow rates, and moisture content in the brick veneers were measured. Major differences in thermal performance were found, with workmanship as the most determining factor. Moisture tolerance was found to be very high for all cavity walls tested. This paper closes with a discussion of the design and workmanship criteria that were highlighted by the research.


Authors:Hugo S.L.C. Hens, Ph.D.; Arnold Janssens, Ph.D.; Wim Depraetere

Citation: Thermal Performance of the Exterior Envelopes of Buildings VIII

Keywords:December, Florida, 2001


File Size : 1 file , 1 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8004
Published : 2001

History


Related products


Best-Selling Products

AS/NZS 10002:2014
Published Date: 10/29/2014
Guidelines for complaint management in organizations
$31.68
AS/NZS 1015:2011
Published Date: 10/07/2011
Records management - Physical storage
$21.582
AS/NZS 1020:1995
Published Date: 03/05/1995
The control of undesirable static electricity
$36.63
AS/NZS 1020:2023
Published Date: 06/02/2023
The control of static electricity in non-hazardous areas
$23.166
AS/NZS 1026:2004
Published Date: 04/29/2004
Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV
$30.492
AS/NZS 1044:1992
Published Date: 08/17/1992
Limits and methods of measurement of radio interference characteristics of household electrical appliances, portable tools and similar electrical apparatus
$33.264