Impact of Low-E WRB Facing an Air Cavity on the R-value of a Wall System PDF

Impact of Low-E WRB Facing an Air Cavity on the R-value of a Wall System PDF

Name:
Impact of Low-E WRB Facing an Air Cavity on the R-value of a Wall System PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
The objectives of this study were to quantify the thermal benefit of Low-E barriers adjacent to an airspace, and to evaluate the thermal resistance of an airspace with and without airflow. The performance of wall systems with three types of weather resistive barriers (WRBs) facing the airspace were evaluated: WRB with Low-E metalized surface, white WRB, and conventional black building paper. The study covers simulations performed with FLUENT® (a 3D Computational Fluid Dynamics model), and a mathematical Analytical Model developed in house. The simulations were compared with experimental measurements on test walls instrumented to determine temperature profiles at various locations within the walls. To estimate the impact of airflow on the airspace contribution to the wall’s effective thermal resistance (R-value), testing was performed for a wall with a controlled introduction of outside air in the airspace and a wall with encapsulated air space (no airflow in the cavity). Both simulations and experimental data indicate that Low-E WRB adjacent to an airspace with or without airflow will improve the thermal performance of the wall when compared to a similar wall with "regular" WRBs, by reducing radiant heat flow through the air cavity. The CFD simulations show that for air cavities up to ¾ in. (19 mm) the effect of convection is minimal while convection dominates over conduction for air cavities above ¾ in. for which there is an effect of airflow on the thermal performance of the wall. An "R-Value Calculator" based on the Analytical Model was developed and validated during this study. The model can be used to evaluate the overall R-value for wall systems with Low-E WRB for enclosed cavities ??¾ in.
File Size : 1 file , 2.3 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 9
Product Code(s) : D-Bldgs19-029
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

AREMA C&S MANUAL
Published Date: 01/01/2021
Communications & Signals Manual - 5-Volume set
AREMA COMM & SIGN
Published Date: 01/01/2018
COMMUNICATIONS & SIGNALS MANUAL - 5-VOLUME SET
AREMA COMM & SIGN
Published Date: 01/01/2019
COMMUNICATIONS & SIGNALS MANUAL - 5-VOLUME SET
AREMA MANUAL FOR RAILWAY ENGINEERING COMBO SET
Published Date: 01/01/2016
Manual for Railway Engineering - Combination Set - Print Version and CD-ROM
$887.4
AREMA MANUAL FOR RAILWAY ENGINEERING
Published Date: 01/01/2021
Manual for Railway Engineering
AREMA PRACTICAL GUIDE TO RAILWAY ENGINEERING COMBO SET
Published Date: 01/01/2016
PRACTICAL GUIDE TO RAILWAY ENGINEERING PLANS - Combination Set (Combination Book/CD-ROM)