Improving Performance of a Variable Speed Refrigeration System Using Smart Control Strategy PDF

Improving Performance of a Variable Speed Refrigeration System Using Smart Control Strategy PDF

Name:
Improving Performance of a Variable Speed Refrigeration System Using Smart Control Strategy PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A refrigeration system was used in cooling and freezing applications controlled by a smart control strategy. This was done using an inverter driven scroll compressor, an inverter driven evaporator fan motors, an inverter driven condenser water pump and an electronic expansion valve. The smart control strategy depends on different controllers; it controls the compressor by artificial neural networks (ANN), the evaporator fan motors by proportional controller, the condenser water pump and the electronic expansion valve by proportional integral differential (PID) controller. Controlling the evaporator fan motors speed was done to maintain a constant supply air temperature, while controlling the condenser water pump speed was done to maintain a constant condensing pressure. The compressor speed was controlled using artificial neural networks (ANN) based on the analyzed data from a preceding experimental results. It was found that operating the refrigeration system using smart control strategy to control the motors speeds improved the performance of the refrigeration system compared to traditional on/off control strategy. Using smart control strategy showed a reduction in the starting operation time compared to the traditional on/off control strategy by 55% in order to achieve the desired room temperature set value. The reduction in operation time to achieve the desired room temperature set value results in total energy saving 60% by using smart control strategy compared to traditional on/off control strategy. The energy saving during system operation in the starting operation period is found to be 11.3%, while the energy saving during the steady state operation time is 11%.


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-ICEB14-20
Published : 2014

History


Related products


Best-Selling Products

AIA AIA NAS SET
Published Date: 04/01/2023
COMPLETE HARDCOPY SET OF AEROSPACE INDUSTRIES ASSOCIATION (AIA) NATIONAL AEROSPACE STANDARDS - INCLUDES ALL CURRENT & INACTIVE FORNEW DESIGN NAS, NASM, NA & METRIC NAS STANDARDS* * 12 VOLUME SET ADD ON 12" GLOBAL BINDER 3" WHITE & (1) GLOBAL BINDER 1" WHITE
AIA ARTC-4
Published Date: 07/01/1960
[BEST AVAILABLE COPY] Electrical Test Procedures for Radomes and Radome Materials
$20.7
AIA NA0001-0006
Published Date: 03/31/2011
RIVET, SOLID, UNIVERSAL HEAD, ALUMINUM AND ALUMINUM ALLOY, METRIC
$19.8
AIA NA0001-0006
Published Date: 01/01/1978
Rivet, Solid - Universal Head Aluminum and Aluminum Alloy, Metric
$19.8
AIA NA0001-0006
Published Date: 12/19/2014
RIVET, SOLID, UNIVERSAL HEAD, ALUMINUM AND ALUMINUM ALLOY, METRIC
$16.5
AIA NA0001-0006
Published Date: 12/19/2014
RIVET, SOLID, UNIVERSAL HEAD, ALUMINUM AND ALUMINUM ALLOY, METRIC
$19.8