Improving the Drying Efficiency of Timber Frame Walls in Cold Climates by Using Exterior Insulation PDF

Improving the Drying Efficiency of Timber Frame Walls in Cold Climates by Using Exterior Insulation PDF

Name:
Improving the Drying Efficiency of Timber Frame Walls in Cold Climates by Using Exterior Insulation PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Safe moisture performance of a structure requires high drying efficiency. Even if a structure has acceptable moisture performance under normal design conditions, long exposure to moist conditions due to high initial moisture content or accidental moisture loads may start biological deterioration. Timber frame walls with rigid exterior sheathing, such as oriented strand board (OSB) or plywood, have relatively low vapor permeance. Use of exterior insulation, made of vapor permeable, open porous material and installed at the cold side of the sheathing, is an effective method to improve the drying efficiency of a wall. The objective of this study was to present how the moisture performance of timber frame walls can be improved with vapor permeable exterior insulation. Numerical simulations and laboratory-scale experiments were used in the analysis. Both moisture content levels and a numerically solved mold growth index were used as criteria in the analyses. Experiments with wall structures having initial moisture loads and temperature gradients were used to study the drying efficiency through sheathing boards with and without exterior insulation. The conditions corresponded to those typical for cold climates experiencing drying: condensation with below and above freezing temperatures at the exterior sheathing. In some conditions, exterior insulation could improve the drying efficiency by nearly a factor of 8. Numerical simulation results show the effect of climate, thickness of exterior insulation, and moisture loads caused by diffusion and initial moisture content on the drying efficiency and moisture performance of timber frame walls.

AUTHOR: Tuomo Ojanen
CITATION: Thermal Performance of the Exterior Envelopes of Buildings VII
KEYWORDS: December, Florida, 1998
YEAR: 1998


File Size : 1 file , 810 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8105
Published : 1998

History


Related products


Best-Selling Products

BS EN ISO/IEC 10373:1995
Published Date: 09/15/1995
Identification cards. Test methods
$92.964
BS EN ISO/IEC 11159:1997
Published Date: 03/15/1997
Information technology. Office equipment. Minimum information to be included in specification sheets. Copying machines
$57.15
BS EN ISO/IEC 11159:1998
Published Date: 09/15/1998
Information technology. Office equipment. Minimum information to be included in specification sheets. Copying machines
$92.964
BS EN ISO/IEC 11172-1:1995
Published Date: 09/01/1995
Information technology. Coding of moving pictures and associated audio for digital storage media at up to about 1,5 Mbit/s-Systems
$110.49
BS EN ISO/IEC 11172-2:1995
Published Date: 09/01/1995
Information technology. Coding of moving pictures and associated audio for digital storage media at up to about 1,5 Mbit/s-Video
$119.634
BS EN ISO/IEC 11172-3:1995
Published Date: 09/01/1995
Information technology. Coding of moving pictures and associated audio for digital storage media at up to about 1,5 Mbit/s-Audio
$119.634