IN-91-21-2 -- Modeling and Optimization of Commercial Building Chiller/Cooling Tower Systems PDF

IN-91-21-2 -- Modeling and Optimization of Commercial Building Chiller/Cooling Tower Systems PDF

Name:
IN-91-21-2 -- Modeling and Optimization of Commercial Building Chiller/Cooling Tower Systems PDF

Published Date:
1991

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Guidelines for specifying condenser water flow rate for commercial building chiller/cooling tower systems have not changed significantly during the past 30 years, while chiller efficiencies have increased and the performance of cooling towers has improved. The present specified value, at design operating conditions, for the condenser water flow rate is typically 2.8 to 3.9 gallons per minute (gpm) per ton of cooling. The purpose of this study is to investigate the effect of using lower condenser water and cooling tower air flow rates on peak power demand, annual energy use, and capital costs for the overall system. In order to do this, mathematical models were developed that simulated the system performance based on manufacturers' component performance data. The results point to using a condenser water flow rate at a design operating condition of 2.0 gpm/ton and across-flow cooling tower air flow rate of 240 cfm/ton (using the present cooling tower sizing criteria). When operating the system at the lower fixed flow rates, savings of 3.5% in system peak demand and 10.5% in annual system energy use were found compared to using flow rates determined by the present guidelines. With the use of optimum variable flow rates, savings of 15.6% in annual energy use charges were found. Reduced equipment costs would also result from the lower pumping requirement.

 

KEYWORDS: calculating, optimisation, commercial, buildings, cooling towers, chillers, performance, regulations, specifications, condensers, water flow, cooling, air flow rate, energy consumption, peak load, costs, components, energy conservation


File Size : 1 file , 920 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-18391
Published : 1991

History


Related products


Best-Selling Products

IEC/PAS 60027-6 Ed. 1.0 en:2004
Published Date: 09/20/2004
Letter symbols to be used in electrical technology - Control technology
$12.6
IEC/PAS 60050-732 Ed. 1.0 b:2007
Published Date: 06/06/2007
International Electrotechnical Vocabulary - Part 732: Computer network technology
$61.2
IEC/PAS 60092-510 Ed. 1.0 en:2009
Published Date: 04/29/2009
Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems
$89.7
IEC/PAS 60099-7 Ed. 1.0 en:2004
Published Date: 04/27/2004
Surge arresters - Part 7: Glossary of terms and definitions from IEC publications 60099-1, 60099-4, 60099-6, 61643-1, 61643-12, 61643-21, 61643-311, 61643-321, 61643-331 and 61643-341
$95.1
IEC/PAS 60191-6-18 Ed. 1.0 en:2008
Published Date: 01/22/2008
Mechanical standardization of semiconductor devices - Part 6-18: General rules for the preparation of outline drawings of surface mounted semiconductor device packages - Design guide for ball grid array (BGA)
$29.1
IEC/PAS 60191-6-19 Ed. 1.0 en:2008
Published Date: 01/22/2008
Mechanical standardization of semiconductor devices - Part 6-19: Measurement methods of package warpage at elevated temperature and the maximum permissible warpage
$32.1