Inefficiency of Passive Plant-Based Systems for Indoor Air Cleaning PDF

Inefficiency of Passive Plant-Based Systems for Indoor Air Cleaning PDF

Name:
Inefficiency of Passive Plant-Based Systems for Indoor Air Cleaning PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Among the techniques that can be applied for indoor air depollution, phytoremediation receives a considerable interest owing its costeffectiveness,its energy efficiency, and its acceptability by the general public. The capacity of potted plants to remove indoor air pollutants has beendemonstrated in many laboratory studies, but their efficiency in real environments has received much less attention. We have performed bothlaboratory controlled experiments in a 300-L chamber and real-scale experiments in a 32 m3 (1130 ft3) room of the MARIA experimentalhouse, exposing one of the most efficient plant, S. aureus, to benzene, carbon monoxide, and to the mixtures of pollutants generated by kerosenespace heaters, incense sticks, or pinewood flooring. The controlled experiments confirm that potted S. aureus plants contribute to the removal ofbenzene and carbon monoxide, both through accommodation on the leaves and degradation by the soil and microorganisms sustained by the roots.The concentration of the pollutant decreases linearly with time, with a total abatement rate in our experimental conditions (6 plants in 300 L) ofabout 2 to 3.10-4 ppm.min-1 for benzene, depending on the initial concentration, in the range 0.5-3 ppm, and 75+/-20 ppm.min-1 for COwhatever the initial concentration in the range 2-15 ppm. The removal of the pollutants by the plant systems is however negligible compared to theremoval through ventilation (ACH 0.6 and 2 h-1), as demonstrated in all the MARIA experiments, where the observed pollutant concentrationsfollow an exponential decrease governed by the air exchange rate, with no difference whether plants are present in the room or not. We thereforeconclude to the inefficiency of passive plant-based systems to improve significantly indoor air quality.


File Size : 1 file , 370 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 7
Product Code(s) : D-2013IAQConf-05
Published : 2013

History


Related products


Best-Selling Products

CAN/CSA-IEC/TS 61000-3-5:12 (R2021)
Published Date: 06/01/2012
Electromagnetic compatibility (EMC) - Part 3-5: Limits - Limitation of voltage fluctuations and flicker in low-voltage power supply systems for equipment with rated current greater than 75 A (Adopted IEC/TS 61000-3-5:2009, edition 2.0, 2009-07)
$14.1
CAN/CSA-IEC/TS 62600-4:22
Published Date: 10/18/2022
Marine energy -- Wave, tidal and other water current converters -- Part 4: Specification for establishing qualification of new technology
$46.8