Interior Insulation Retrofit of a Brick Wall Using Vacuum Insulation Panels: Design of a Laboratory Study to Determine the Hygrothermal Effect on Existing Structure and Wooden Beam Ends PDF

Interior Insulation Retrofit of a Brick Wall Using Vacuum Insulation Panels: Design of a Laboratory Study to Determine the Hygrothermal Effect on Existing Structure and Wooden Beam Ends PDF

Name:
Interior Insulation Retrofit of a Brick Wall Using Vacuum Insulation Panels: Design of a Laboratory Study to Determine the Hygrothermal Effect on Existing Structure and Wooden Beam Ends PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The increasing demand on energy-efficient buildings requires energy retrofitting measures in the existing building stock.Conventional thermal insulation materials, such as mineral wool and expanded polystyrene (EPS), demand a thick layer of insulationto reach the energy targets. Vacuum insulation panels (VIPs) are a novel thermal insulation component with 5–10 timeslower thermal conductivity than the conventional insulation materials, depending on the VIP ageing state. The thermal transmittanceof the building envelope can thereby be substantially reduced using a limited additional insulation thickness. Previousresearch has shown that interior energy retrofitting of exterior walls may increase the moisture content of the walls and increasesthe risk of freeze-thaw damages at the surface. This study analyzes the hygrothermal consequences on a 250 mm (9.8 in.) thickbrick wall retrofitted with 20 mm (0.8 in.) interior VIP (glued directly on the plastered brick wall). Hygrothermal simulationsin WUFI 2D are used to study the hygrothermal effects by different material properties and boundary conditions. Apart from thematerial properties, the amount of driving rain available at the surface is the most important influential parameter in the simulations.The conclusions from this study are used to plan a measurement study in a climate simulator where driving rain and solarradiation will be simulated.

Presented at Thermal Performance of Exterior Envelopes of Whole Buildings XII, December 2013


File Size : 1 file , 2.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-BldConf13-33
Published : 2013

History


Related products


Best-Selling Products

IEEE/ANSI 101-1987
Published Date: 12/31/1988
IEEE Guide for the Statistical Analysis of Thermal Life Test Data
$67.2
IEEE/ANSI 18-1980
Published Date: 12/15/1980
IEEE Standard for Shunt Power Capacitors
$23.4
IEEE/ANSI 213-1961
Published Date: 04/06/1961
ANSI/IEEE Radio Interference: Methods of Measurement of Conducted Interference Output to the Power Line from FM and Television Broadcast Receivers in the Range of 300 kHz to 25 MHz
$16.5
IEEE/ANSI 262-1968
Published Date: 1968
USA Standard Test Code for Distribution, Power and Regulating Transformers, and Shunt Reactors
$19.5
IEEE/ANSI 315-1975
Published Date: 12/29/1975
IEEE Standard for Graphic Symbols for Electrical and Electronics Diagrams (Including Reference Designation Letters)
$39.9
IEEE/ANSI 315A-1986
Published Date: 09/12/1986
American National Standard - Supplement to Graphic Symbols for Electrical and Electronics Diagrams
$12.9