Name:
ITU-T K.147 PDF
Published Date:
07/01/2023
Status:
[ Active ]
Publisher:
International Telecommunication Union-T
This Recommendation describes overvoltages and overcurrents protection of information technology equipment with digital port including Ethernet port regarding the testing found in [ITU-T K.20], [ITU-T K.21], [ITU-T K.44], [ITU-T K.45] and [ITU-T K.117]. Topics covered are:
• overvoltage and overcurrent events coupling into the network system depending on
– implementation condition,
– system configuration,
– powering condition (data only or provision of network powering) and
– link insulation;
• lightning surge resistibility test circuit approaches;
• power fault resistibility test circuit approaches;
• resistibility test circuit applicability to [ITU-T K.20], [ITU-T K.21], [ITU-T K.44], [ITU-T K.45] and [ITU-T K.117].
| Edition : | 23# |
| File Size : | 1 file |
| Number of Pages : | 60 |
| Published : | 07/01/2023 |