Progressive migration of a telecommunication/ information and communication technology site to 400 VDC sources and distribution

Publisher:
International Telecommunication Union-T

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$12.3
Need Help?

This Recommendation defines solutions for progressive migration of information and communication technology (ICT) sites (telecommunication and data centres) to up to 400 V direct current (400 VDC) distribution and direct use of up to 400 VDC powering ICT equipment from 400 VDC sources. The Recommendation also defines different major use case options and migration scenarios, such as:

– migration to an up to 400 VDC of telecommunication site power solution;

– migration to an up to 400 VDC of data centre power solution;

– migration with up to 400 VDC power transfer between existing −48 V centralized sources to high power density −48 V equipment, such as routers;

– integration of up to 400 VDC remote powering;

– combined architecture with up to 400 VDC and AC sources and distributions possibly using hybrid power interfaces on ICT equipment.

For each of these, this Recommendation describes many possible options and characteristics, such as:

– migration architecture with up to 400 VDC/−48 V conversion to power existing −48 V equipment using existing −48 V room distribution; 

– conditions for tripping overcurrent protection devices without −48 V batteries;

– migration architecture with up to 400 VDC/AC inverter as an alternative to the AC UPS to power existing AC equipment;

– use of local up to 400 VDC for remote powering of ICT equipment;

– coupling up to 400 VDC systems to a local REN source or to a DC microgrid;

– possibility of conversion between battery and up to 400 VDC distribution, e.g., for long power distribution or short-circuit current or battery technology (e.g., lithium-ion).

This Recommendation also gives a saving assessment frame reference to define the best migration scenario and its steps by considering energy, resource, environmental impact and cost savings based on functional aspects such as modularity, flexibility, reliability, efficiency and distribution losses, as well as maintenance evolution when migrating from −48 V or alternating current (AC) to up to 400 VDC solutions. This also includes consideration of load architecture evolution dependent on use cases (e.g., telecommunication site, data centres).


Edition : 18
File Size : 1 file
Number of Pages : 40
Published : 05/01/2018

History


Related products

ITU-T X.237 SPANISH
Published Date: 04/01/1995
TECNOLOGÍA DE LA INFORMACIÓN – INTERCONEXIÓN DE SISTEMAS ABIERTOS – PROTOCOLO EN MODO SIN CONEXIÓN PARA EL ELEMENTO DE SERVICIO DE CONTROL DE ASOCIACIÓN: ESPECIFICACIÓN DE PROTOCOLO
$9.9
ITU-T X.1712
Published Date: 10/01/2021
Security requirements and measures for quantum key distribution networks – key management
$9.9
ITU-T T.10 BIS
Published Date: 11/01/1988
DOCUMENT FACSIMILE TRANSMISSIONS IN THE GENERAL SWITCHED TELEPHONE NETWORK
$6
ITU-T J.192 SPANISH
Published Date: 11/01/2005
Pasarela residencial para soportar la entrega de servicios de datos por cable
$110.4

Best-Selling Products

NS-CEN ISO/TS 15011-6:2012/AC:2012
Published Date: 07/15/2012
Health and safety in welding and allied processes - Laboratory method for sampling fume and gases - Part 6: Procedure for quantitative determination of fume and gases from resistance spot welding - Technical Corrigendum 1 (ISO/TS 15011-6:2012/Cor 1:2012)
Free Download