KC-03-06-2 -- Passive Performance of a High-Mass Residence: Actual Data vs. Simulation PDF

KC-03-06-2 -- Passive Performance of a High-Mass Residence: Actual Data vs. Simulation PDF

Name:
KC-03-06-2 -- Passive Performance of a High-Mass Residence: Actual Data vs. Simulation PDF

Published Date:
2003

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The public domain building simulation software EnergyPlus® is under development. It is to have the capability to simulate radiant cooling and heating panel systems. A recently completed ASHRAE research project (RP-1140) funded the development of a data set for the validation of simulation tools for radiant/convective systems. This study represents an attempt, using these data, to validate EnergyPlus’ ability to predict a building’s performance—in this case, only the passive performance of an envelope-dominated heavy mass residence. Although the case study house happens to have a radiant panel cooling and heating system for which data are available, the simulation accomplished for this paper concerns only the passive operation of the envelope. The logic being that a simulation tool must first be able to predict passive performance if it is to reliably predict active radiant system performance, since the two systems interact. The results were mixed, but most of the simulation results matched favorably with the actual performance for variables evaluated. Various interior temperatures showed the best matches, although there was up to a two-hour shift in highs and lows. The exterior surface temperatures were less reliable with a variance as much as 10°F for the roof surface and a shift up to one-hour in highs and lows for the wall surface. Further work is planned to see if the source of the discrepancy is inaccurate solar radiation component data, direct solar radiation.

Units: Dual


File Size : 1 file , 4.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-20866
Published : 2003

History


Related products


Best-Selling Products

HOLDEN ETPSL0026
Published Date: 11/01/2012
H Point Measurement
$23.4
HOLDEN ETPSL0039
Published Date: 05/01/2012
ADR 21/00 Instrument Panel Impact Test Procedure
$23.4
HOLDEN ETPSL0044
Published Date: 11/01/2012
Demisting of Vehicle Windscreen for Categories MA MC ADR 15
$23.4
HOLDEN ETPSL0101
Published Date: 05/01/2012
Closure Stiffness Testing
$23.4
HOLDEN ETPSLR0008
Published Date: 11/01/2012
Door Weatherstrip Slam Test
$23.4
HOLDEN ETPSLR0061
Published Date: 11/01/2012
Steering Gear Impact Test
$23.4