KC-84-03-1 -- Heat Pump Design for Aquifer Seasonal Heating—Only Thermal Energy Storage Systems PDF

KC-84-03-1 -- Heat Pump Design for Aquifer Seasonal Heating—Only Thermal Energy Storage Systems PDF

Name:
KC-84-03-1 -- Heat Pump Design for Aquifer Seasonal Heating—Only Thermal Energy Storage Systems PDF

Published Date:
1984

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Aquifer seasonal thermal energy storage (ASTES) is considered in conjunction with residential-size water-source heat pumps for providing heating. The system investigated consists of a confined aquifer, which has two wells (injection and production) and numerous heat pumps attached by a distribution network. A model of the system was developed, and yearly evaluations were made to determine the influences of several parameters on overall system performance. Two important constraints on the study were that (1) only heating, rather than heating and cooling, was to be provided, and (2) a single pair of wells (a doublet) was to be used rather than a system of multiple production and injection wells. Energy consumed by pumping equipment to inject and withdraw fluid from the aquifer and circulate fluid through a recharge system is included in the overall system performance.

The modeling and evaluation of the system delineated how the energy-efficiency feasibility of such systems is a function of a number of geological, geophysical, engineering, architectural, and climatic variables. The work presented here represents a start to define some bounds of this feasibility, primarily with regard to the engineering design variables. From the outset, the heat pump design, particularly the DTW) was identified as an important factor. The results show that the regions (ranges of geological, geophysical, architectural, and climatic parameters) of energy feasibility are greatly expanded when the heat pump is designed for the optimum (or near optimum) DTW, and when the heat pump performance is improved from the "Off-the-Shelf, Average" performance to that of either the "Projected, Heating Only," or the "Off-The-Shelf, Single-Unit" performance considered here. This expansion with regard to DTW, is the greatest when the aquifer parameters such as permeability, height, recovery factor, and safety factor lie toward the least desirable end of their range. Perhaps as important, the expansion, with regard to DTW, also becomes more significant as the load that is served increases. The results also illustrate that the recharge system, regardless of the source of the thermal energy, can have a significant influence on the energy feasibility of such systems. For some ranges of parameters, these systems, particularly with redesigned heat pumps, show good energy-efficiency feasibility, providing a waste thermal-energy source for use in recharge is available.


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 18
Product Code(s) : D-KC-84-03-1
Published : 1984

History


Related products


Best-Selling Products

NBBI NB23-2004
Published Date: 01/01/2005
National Board Inspection Code - NBIC, 2004 Edition
NBBI NB23-2007 Part 2
Published Date: 12/31/2007
National Board Inspection Code - NBIC, 2007 Edition - Part 2 - Inspection
NBBI NB23-2011 Part 1
Published Date: 2011
National Board Inspection Code - NBIC, 2011 Edition - Part 1 - Installation
NBBI NB23-2015
Published Date: 2015
National Board Inspection Code - NBIC, 2015 Edition (Three Volumes)
NBBI NB23-2019 Part 1
Published Date: 2019
National Board Inspection Code - NBIC, 2019 Edition - Part 1 - Installation
NBBI NB23-2019 Part 2
Published Date: 2019
National Board Inspection Code - NBIC, 2019 Edition - Part 2 - Inspection