LB-17-C041 -- Retrofit of Commercial Buildings Using a Gas Heat Pump System PDF

LB-17-C041 -- Retrofit of Commercial Buildings Using a Gas Heat Pump System PDF

Name:
LB-17-C041 -- Retrofit of Commercial Buildings Using a Gas Heat Pump System PDF

Published Date:
2017

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The air-conditioning system is a big energy consumer of buildings, representing around 30% of total energy consumption on commercial buildings, considering the climate of the city of Sao Paulo, Brazil. The adoption of air-conditioning systems that use alternative sources of supply can contribute significantly on energy costs reduction and, considering the current Brazilian energy scenario, the use of natural gas source technologies could be advantageous. In office buildings, the use of a Gas Heat Pump air-conditioning system may enable to meet thermal loads with reduced costs, if compared to a conventional electrical system, with the advantage of reducing the energy demand of the whole building, mainly due to on-peak energy rates and considering reduction on electric infrastructure. Considering those issues, the purpose of this study was to technically investigate the retrofit of a conventional electric air-conditioning system of an existing office building to a Gas Heat Pump system. A data assembling of operating office buildings in the city of Sao Paulo with potential for retrofit was raised and analysed, and a representative case study in an existing office building was developed, using computer simulation to evaluate energy performance of the proposed system versus the existing system. Results show that 16.7% of the data assembling have technical feasibility on performing a retrofit of the air-conditioning system, considering parameters adopted in this study. The specific case study presented an advantageous output on trading the energy source of the air-conditioning system from electricity to natural gas, showing annual energy savings of 30.3% in cost for GHP Scenario, with a 38% reduction in annual electricity consumption./p>

 


File Size : 1 file , 750 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-LB-17-C041
Published : 2017
Units of Measure : Dual

History


Related products


Best-Selling Products

FAS A-A-1270 VALID NOTICE 4
Published Date: 01/17/2012
ADHESIVE, POLYVINYL ACETATE EMULSION, GENERAL PURPOSE
$8.1
FAS A-A-1270
Published Date: 04/16/1996
ADHESIVE, POLYVINYL ACETATE EMULSION, GENERAL PURPOSE
$39.6
FAS A-A-1340A VALID NOTICE 1
Published Date: 11/06/2019
Wrench, Box, Stub End Type, Offset Handle
$8.1
FAS A-A-1340A
Published Date: 03/12/2002
WRENCH, BOX, STUD END TYPE, OFFSET HANDLE
$17.1
FAS A-A-1341A VALID NOTICE 1
Published Date: 11/06/2019
Wrench, Box, Stub End Type, Straight Handle
$8.1
FAS A-A-1341A
Published Date: 02/05/2002
WRENCH, BOX, STUD END TYPE, STRAIGHT HANDLE
$17.1