LO-09-006 -- A Design Tool for Hybrid Geothermal Heat Pump Systems in Cooling-Dominated Buildings PDF

LO-09-006 -- A Design Tool for Hybrid Geothermal Heat Pump Systems in Cooling-Dominated Buildings PDF

Name:
LO-09-006 -- A Design Tool for Hybrid Geothermal Heat Pump Systems in Cooling-Dominated Buildings PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A practical method for designing hybrid geothermal heat pump (GHP) systems that use closed-loop, earth heat exchangers installed in vertical boreholes is presented. The design difficulty with hybrid GHP systems is inherently an optimization problem that is best solved with a computer-based system simulation method. Many parameters can be optimized and there is no unique expression of the objective function. In this work the optimization problem is defined as balancing the annual thermal loads on the ground by minimizing the borehole heat exchanger length and appropriately sizing supplemental equipment. The supplemental equipment examined in this work has been limited to direct-contact evaporative cooling towers.

The design method for GHP systems was developed from results of 91 detailed computer simulations. Three dimensionless groups containing key GHP design parameters were identified using the Buckingham Pi Theorem, and correlated with a fitted surface equation. With typical design parameters available to a practitioner, the design method developed here can be used to estimate the total ground loop length for stand-alone GHP systems, along with the quantity of annual energy required to balance the annual ground loads. With additional input parameters also readily available to designers, the capacity of a cooling tower can be calculated, along with the corresponding reduced borehole heat exchanger length. Cooling tower capacity is calculated using an annual equivalent full load hour concept.\

 

Units: SI 


File Size : 1 file , 880 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-LO-09-006
Published : 2009

History


Related products


Best-Selling Products

AAMI/ISO 10993-1:2003
Published Date: 12/01/2003
Biological Evaluation of Medical Devices Part 1: Evaluation and Testing
$26.4
AAMI/ISO 10993-1:2009 Erratum
Published Date: 06/10/2013
Erratum for Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
Free Download
AAMI/ISO 10993-1:2009/(R)2013
Published Date: 09/03/2009
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process; Includes Erratum (2013)
AAMI/ISO 10993-1:2018
Published Date: 04/27/2020
Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process
$82.5
AAMI/ISO 10993-10:2010/(R)2014
Published Date: 09/04/2010
Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization
$82.5
AAMI/ISO 10993-11:2006/(R)2014
Published Date: 10/19/2006
Biological evaluation of medical devices - Part 11: Tests for systemic toxicity