LO-09-021 -- Evaluation of a Novel Liquid-Flooded Ericsson Cycle Cooler for Vending Machine Applications PDF

LO-09-021 -- Evaluation of a Novel Liquid-Flooded Ericsson Cycle Cooler for Vending Machine Applications PDF

Name:
LO-09-021 -- Evaluation of a Novel Liquid-Flooded Ericsson Cycle Cooler for Vending Machine Applications PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Research on a novel implementation of an Ericsson cycle heat pump for near ambient refrigeration applications was performed. The concept, termed a liquid-flooded Ericsson cooler (LFEC), uses liquid flooding of the compressor and expander to approach isothermal compression and expansion processes. A numerical simulation of the cycle was developed and parametric studies were performed to explore the sensitivity of the cycle to changes in various system parameters such as, pressures, heat exchanger effectiveness and working fluids. The goal of the study was to assess the viability of the technology for vending machine applications. It was found that the target cooling coefficient of performance (COP) of 1.25 could be attained if the adiabatic efficiency of the compressor and expander were 85%.

 

Units: Dual 


File Size : 1 file , 870 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 14
Product Code(s) : D-LO-09-021
Published : 2009

History