LO-09-029 (RP-1373) -- Air Distribution Effectiveness with Stratified Air Distribution Systems PDF

LO-09-029 (RP-1373) -- Air Distribution Effectiveness with Stratified Air Distribution Systems PDF

Name:
LO-09-029 (RP-1373) -- Air Distribution Effectiveness with Stratified Air Distribution Systems PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Stratified air distribution systems such as Traditional Displacement Ventilation (TDV) and Under-Floor Air Distribution (UFAD) systems have been known to provide better indoor air quality. This study examined the influence of several key design parameters on air distribution effectiveness by using a validated CFD program. The parameters studied were space type, diffuser number, supply air temperature, cooling load, return location, total airflow rate, and secondary heating system. Six indoor spaces were investigated to develop a database: classrooms, office spaces, workshops, restaurants, retail spaces, and auditoriums. The air distribution effectiveness at breathing zone was at 1.1 ~ 1.6 for offices, classrooms, restaurants and retail shops, and 1.6 ~ 2.0 for workshops and auditoriums. The spaces with a high ceiling such as workshops and auditoriums had higher air distribution effectiveness than those with a low ceiling. Thus, the stratified air distribution systems are better for spaces with a high ceiling. The air distribution effectiveness for the TDV and UFAD with low throw height was similar and was higher than that of UFAD with high throw height and mixing ventilation. A database was established containing 102 cases of the parametric study results. With this database, the investigation identified the six most important parameters to follow in developing a set of correlation equations for calculating air distribution effectiveness through statistical analysis. The air distribution effectiveness calculated by the equations was mostly within 10% of that for the corresponding case in the database.

 

Units: Dual 


File Size : 1 file , 1.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-LO-09-029
Published : 2009

History


Related products


Best-Selling Products

PFI ES11
Published Date: 01/01/1996
Permanent Marking on Piping Materials
PFI ES16
Published Date: 01/01/1985
Access Holes, Bosses and Plugs for Radiographic Inspection of Pipe Welds
PFI ES1
Published Date: 07/01/1995
Internal Machining & Solid Machined Backing Rings for Circumferential Butt Welds
PFI ES20
Published Date: 01/01/1997
Wall Thickness Measurement by Ultrasonic Examination
PFI ES21
Published Date: 01/01/1992
Internal Machining & Fit-Up of GTAW Root Pass Circumferential Butt Welds
PFI ES22
Published Date: 01/01/1995
Recommended Practice for Color Coding of Piping Materials