LO-09-082 -- Laboratory Evaluation and Modeling of Electrostatic Precipitation of PM Emissions from Poultry Buildings PDF

LO-09-082 -- Laboratory Evaluation and Modeling of Electrostatic Precipitation of PM Emissions from Poultry Buildings PDF

Name:
LO-09-082 -- Laboratory Evaluation and Modeling of Electrostatic Precipitation of PM Emissions from Poultry Buildings PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Particulate matter (PM) emissions from the poultry industry are a major pollution concern. Development of an effective PM mitigation technology is urgently needed. In this study, the potential of an electrostatic precipitator (ESP) for collecting PM emissions from poultry facilities was evaluated using a commercial ESP unit under simulated laboratory conditions. The effects of operating parameters such as charger voltage, superficial air velocity and PM concentration on the performance of a two-stage plate ESP were evaluated. An empirical model for predicting ESP performance was developed. Preliminary factor screening analyses have shown that charger voltage (7 kV to 10 kV) and superficial air velocity [1 m/s (200 ft/min) to 5 m/s (1000 ft/min)] affect ESP performance significantly while PM concentration (2.5 mg/m3 to 5 mg/m3) had negligible effect (a=0.05). The ESP collection efficiency increased with voltage and decreased with velocity. The relationship between charger voltage and superficial air velocity and PM collection efficiency for particles within size ranges of 0.3-0.5, 0.5-1, 1-5, 5-10, 10-25, >25 , PM1, PM5, and PM10 were apparently nonlinear. The ESP performance approached a peak point at 9 kV charger voltage and 1 m/s air velocity. The optimized operating condition to be used at an actual farm would depend on the desired degree of PM collection. To collect at least 90% of all particles, the operating conditions were 9 kV and 2.5 m s-1. The power consumption of the ESP to collect 90% of the total particles is 90 watts/m2(29 BTU/h/ft2) of duct cross-sectional area. The ESP unit produced very negligible amount of ozone (<50 ppbv) at the extreme operating condition for ozone generation, which is at 10 kV and 1 m/s (200 ft/min) air flow.

 

Units: Dual


File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 19
Product Code(s) : D-LO-09-082
Published : 2009

History


Related products


Best-Selling Products

AIST/ISS DIR-20
Published Date: 01/01/2020
2020 Directory Iron and Steel Plants
$56.7
AIST/ISS PB-084
Published Date: 01/01/2002
Rolls for the Metalworking Industries
$52.5
AIST/ISS PB-099
Published Date: 01/01/2004
Continuous Casting, Volume 10: Tundish Operations
$29.4
AIST/ISS PB-126
Published Date: 01/01/2003
Austenite Formation and Decomposition
$42
AIST/ISS PB-127
Published Date: 01/01/2003
Modeling, Control, and Optimization in Ferrous and Non-Ferrous Industry
$51.9
AIST/ISS PB-210
Published Date: 01/01/2010
Bar Steels: Steel Products Manual
$31.5