LV-22-C010 -- Preliminary Investigation of Active Demand Flexibility Control at Air Handling Units using Energy Feedback Control PDF

LV-22-C010 -- Preliminary Investigation of Active Demand Flexibility Control at Air Handling Units using Energy Feedback Control PDF

Name:
LV-22-C010 -- Preliminary Investigation of Active Demand Flexibility Control at Air Handling Units using Energy Feedback Control PDF

Published Date:
2022

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Grid-interactive efficient buildings (GEBs) require quick and accurate manipulation of flexible electrical loads. Heating, ventilating, and air conditioning (HVAC) loads are particularly well suited for demand flexibility control by utilizing thermal mass in building structures. The HVAC load and its responding zone temperature (ZT) can be optimized by model predictive control (MPC) to minimize the operation cost with the indoor comfort constraint. However, due to the lack of reliable and affordable energy meters, the current HVAC demand control is implemented using ZT feedback control with the responding ZT optimized by MPC as the setpoint and the HVAC load as the response. Unfortunately, the building thermal mass makes the actual HVAC load significantly different than the optimized HVAC load, which is the on-demand setpoint, with potential demand penalty. Low-cost virtual flow meter technology makes the cooling load measurement at air handling units (AHUs) available, thus energy feedback control can be applied to actively control the cooling load of AHUs at its on-demand setpoint. The objective of the paper is to preliminarily investigate the demand flexibility control performance of the energy feedback control at AHUs. First, the energy feedback control at AHUs is introduced. Then, the performance of a single zone AHU is simulated and compared between the ZT feedback control and energy feedback control. Finally, a field experiment is conducted on a 7-ton single duct variable air volume AHU with these two different controls. Experimental results show that the cooling load with the current ZT feedback control drops to the on-demand setpoint after 25 minutes. On the other hand, the energy feedback control can reduce the cooling load to the on-demand setpoint in less than 3 minutes. Therefore, the active energy feedback control can significantly advance the current ZT feedback control by quickly and accurately controlling the cooling load at AHUs to avoid the demand penalty.
File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-LV-22-C010
Published : 2022
Units of Measure : Dual

History


Related products


Best-Selling Products

IFAI CPAI-75
Published Date:
Rate of Burn Specifications for Sleeping Bags
$60
IFAI CPAI-84
Published Date: 01/01/2021
Specification for Flame-resistant Materials Used in Camping Tentage
IFAI MARINE FABRICATOR DESIGN
Published Date:
Marine Fabricator Design & Fabrication Manual
$17.4
IFAI STATE OF THE INDUSTRY
Published Date: 01/01/2021
State of the Industry
$187.8
IFAI USIFI-DTL 55308A
Published Date: 03/16/2010
Detail Specification — Cloth and Strip, Laminated or Coated, Vinyl, Reinforced, High Strength, Flexible
$37.2