LV-22-C049 - Challenges and Opportunities of using Closed Cavity Façade (CCF) for Improving Energy Efficiency and Indoor Environmental Quality (IEQ) in Office Buildings in US Climates PDF

LV-22-C049 - Challenges and Opportunities of using Closed Cavity Façade (CCF) for Improving Energy Efficiency and Indoor Environmental Quality (IEQ) in Office Buildings in US Climates PDF

Name:
LV-22-C049 - Challenges and Opportunities of using Closed Cavity Façade (CCF) for Improving Energy Efficiency and Indoor Environmental Quality (IEQ) in Office Buildings in US Climates PDF

Published Date:
2022

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

As human skin is an important barrier and thermal regulator of the human body, the building "skin" is the first critical element in defining goals for building energy efficiency and Indoor Environmental Quality (IEQ). The glazing part of a building envelope is particularly critical because it is the most vulnerable envelope element to heat gain and heat loss accounting for around 50% of the building's energy consumption. Increasingly stringent regulations imposed over time mandate the adoption of high-performance façades.

In this regard, in the second half of the twentieth century, Double Skin Façades (DSF) were developed. However, with cavity widths varying from 50 cm (1.64 ft) up to 2 m (6.56 ft), DSFs are rather space-consuming and require high installation and maintenance costs. For this purpose, a Closed Cavity Façade (CCF) was developed as a specific DSF system. In its simplest form, a CCF consists of a double or triple glazing unit (DGU or TGU) on the inner layer and single glazing on the outer one, forming a sealed non-ventilated cavity (about 20 cm width) with automated blinds in between which, given its dynamic behaviour, can contribute to balance the demand for energy saving and enhancement of IEQ. This study, using Energy Plus and IDA ICE building performance simulation tools, investigates the performance of several CCF configurations and geometries, for the eight climate zones of the USA, and compares them to the baseline (a DGU). MATELab, an office-like test facility at the University of Cambridge was used as the model for the simulations, which was beforehand experimentally validated.

The CCF configurations investigated, led to a decrease of energy consumption in the range of 19-44% compared to the conventional DGU used as the baseline. This is mainly attributed to the improved thermal transmittance and solar heat gain coefficient (SHGC) because of integrating Venetian blinds in the cavity. A higher performance improvement is observed in cooling-dominated locations since CCF reduces solar gain through the façade, which is the main contributor to energy consumption. Furthermore, it was shown that suitable selection of the components of a CCF system (such as the colour of blinds and the type of coatings) results in an additional 1-2% improvement of its thermal performance, cutting down overheating phenomena, retaining the glass cavity temperatures below the critical value, and reducing the radiant discomfort providing extra benefits in terms of IEQ and occupant's productivity.

File Size : 1 file , 3.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-LV-22-C049
Published : 2022
Units of Measure : Dual

History


Related products


Best-Selling Products

ITU-R 27
Published Date: 01/01/1993
HF Field-Strength Measurement Campaign
$8.4
ITU-R 346-1
Published Date: 01/01/1970
(WITHDRAWN) Four-Frequency Diplex Systems - Section 3Ca - Radiotelegraph Circuits
$0.3
ITU-R 41-1 FRENCH
Published Date: 01/01/2000
Collaboration avec l'Organisation internationale de normalisation (ISO) et la Commission électrotechnique internationale (CEI) sur les techniques de la radiodiffusion
ITU-R 41-1 SPANISH
Published Date: 01/01/2000
Colaboración con la Organización Internacional de Normalización (ISO) y la Comisión Electrotécnica Internacional (CEI) sobre tecnologías de radiodifusión
ITU-R 903-2 SPANISH
Published Date: 01/01/1990
TRANSMISIÓN DIGITAL EN EL SERVICIO MÓVIL TERRESTRE
ITU-R 917-2 SPANISH
Published Date: 01/01/1990
NIVELES ADMISIBLES DE INTERFERENCIA EN LOS CANALES TELEFÓNICOS DEL SERVICIO MÓVIL MARÍTIMO POR SATÉLITE