Modeled Air Quality and Energy Use Impacts of UVGI for Cooling Coil Biofouling Mitigation PDF

Modeled Air Quality and Energy Use Impacts of UVGI for Cooling Coil Biofouling Mitigation PDF

Name:
Modeled Air Quality and Energy Use Impacts of UVGI for Cooling Coil Biofouling Mitigation PDF

Published Date:
2013

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Biofouling of cooling coils increases air-side flow resistance and decreases overall heat transfer coefficient, which may increase HVAC systemenergy use. Irradiation of cooling coil surfaces with ultraviolet light (Ultraviolet Germicidal Irradiation, or UVGI), can control surface biofoulingand simultaneously inactivate airborne microorganisms to improve indoor air quality (IAQ). An annual simulation of a representative officebuilding in the Philadelphia area was created to investigate the potential energy savings and IAQ benefits of cooling coil irradiation. ThreeHVAC system alternatives were considered: a single-zone constant air volume (CAV) system with either constant or variable speed fan, and asingle zone variable speed fan (variable air volume) VAV system, each with a two-way valve controlled chilled water coil and constant speedpump. Coil fouling effects for untreated coils were based on recent peer-reviewed experimental studies. The principal energy-related outputsevaluated were fan and pump energy use and the number of hours of operation outside of space set points. Elimination of biofouling caused adecrease in pump energy use ranging from 15% to 21% for all systems. Fan energy decreased 15.3% and 27.3% for a VFD (variable frequencydrive)-equipped CAV and VAV system, respectively. Fan energy increased 12% upon application to the constant speed CAV system due to thefact that fouling reduced airflow rate, and therefore reduced capacity. Prediction of infection risk using an application of a modified Wells-Rileyequation modified to account for equivalent ventilation due to UVGI predicted economic benefits between $5000 and $20000, but the question ofwhat to use as a baseline has a significant effect on projected savings (that is, the economic benefit of a percentage reduction in sick leave isproportional to a company's current sick leave rates).


File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-2013IAQConf-30
Published : 2013

History


Related products


Best-Selling Products

CAN/CSA-ISO/IEC TS 11801-9903:21
Published Date: 10/11/2021
Information technology - Generic cabling systems for customer premises - Part 9903: Matrix modelling of channels and links (ISO/IEC TS 11801-9903:2021, IDT)
$51.9
CAN/CSA-ISO/IEC TS 16085-05
Published Date: 10/01/2005
Information Technology - Software Life Cycle Processes - Risk Management (Adopted ISO/IEC 16085:2004 / IEEE 1540-2001, first edition, 2004-10-01)
$34.5
CAN/CSA-ISO/IEC TS 17961:18 (R2022)
Published Date: 01/01/2018
Information technology - Programming languages, their environments and system software interfaces - C secure coding rules (Adopted ISO/IEC TS 17961:2013, first edition, 2013-11-15, including adopted technical corrigendum 1:2016)
$62.7
CAN/CSA-ISO/IEC TS 18661-5:18 (R2022)
Published Date: 01/01/2018
Information technology - Programming languages, their environments, and system software interfaces - Floating-point extensions for C - Part 5: Supplementary attributes (Adopted ISO/IEC TS 18661-5:2016, first edition, 2016-08-15)
$41.7
CAN/CSA-ISO/IEC TS 19570:20
Published Date: 03/01/2020
Programming Languages - Technical Specification for C++ Extensions for Parallelism (Adopted ISO/IEC TS 19570:2018, second edition, 2018-11)
$51
CAN/CSA-ISO/IEC TS 19608:19
Published Date: 10/01/2019
Guidance for developing security and privacy functional requirements based on ISO/IEC 15408 (Adopted ISO/IEC TS 19608:2018, first edition, 2018-10)
$51