NO-94-13-5 -- A Comparative Study of Proportional Flux-Modulation and Various Types of Temperature-Modulation Approaches for Radiant Floor-Heating System Control PDF

NO-94-13-5 -- A Comparative Study of Proportional Flux-Modulation and Various Types of Temperature-Modulation Approaches for Radiant Floor-Heating System Control PDF

Name:
NO-94-13-5 -- A Comparative Study of Proportional Flux-Modulation and Various Types of Temperature-Modulation Approaches for Radiant Floor-Heating System Control PDF

Published Date:
1994

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

With renewed interest in radiant floor-heating systems in the past decade, the issue of optimum control has become controversial. Friedlander (1986) and Adelman (1988) recommend outdoor reset control based on the principle that there is a direct, linear relationship between outside temperature and the required supply water temperature. ASHRAE (1987) also states that the supply water temperature should be varied in accordance with outside temperature due to the time lag between thermostat demand and heat delivery to the space. In contrast, MacCluer (1989) proposed the concept of proportional flux-modulation and claimed that the rate of heat sent to the floor slab must be controlled, not the temperature. To evaluate these issues, a comparative study of proportional flux-modulation and various types of temperature-modulation approaches was conducted through physical experiments in a laboratory setting during the 1990-91 heating season (Leigh 1991a, 1991b). The results show that proportional flux-modulation favourably compares with various types of temperature-modulation approaches by maintaining a stable indoor temperature around the setpoint and by demonstrating immediate response to any internal load disturbance. Temperature-modulation approaches show sensitivity to the reset ratio. Temperature modulation via flow inhibition shows sensitivity to the boiler water temperature. Indoor temperature feedback is highly recommended to help compensate for these potential errors and thus minimise the offset from the setpoint with temperature modulation.

KEYWORDS: heat flow, temperature control, heating, floor heating, radiant heating, water temperature, controls, comparing, room temperature, outdoor temperature, optimisation.


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17880
Published : 1994

History


Related products


Best-Selling Products

NZS 10011
Published Date:
Guidelines for auditing quality systems
NZS 1011:1964
Published Date:
Methods for bend testing of metals
NZS 1153
Published Date:
Specification for screw gauge limits and tolerances
NZS 1188:1954
Published Date:
Fire-doors and fire-windows
NZS 1227
Published Date:
Specification for Unified screw threads
NZS 1340:1970
Published Date:
Thermal insulating materials for buildings