NO-94-30-2 -- Application of a Nuclear Containment Analysis Code to Transient Natural Convection Analysis PDF

NO-94-30-2 -- Application of a Nuclear Containment Analysis Code to Transient Natural Convection Analysis PDF

Name:
NO-94-30-2 -- Application of a Nuclear Containment Analysis Code to Transient Natural Convection Analysis PDF

Published Date:
1994

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

A computer program was developed for performing thermal hydraulic transient analysis of nuclear power plant containment buildings. The code package includes pre- and post-processors that facilitate the development of compartmental node models for the analysis of a variety of thermal hydraulic problems. This program was used on the analysis of thermal transients resulting from the postulated failure of all ventilation fans in the river intake pump house (housing eight 662 kW (700 hp) and eight 932 kW (1250 hp) pumps) at a nuclear power plant. This paper describes the development of a model for the structure and application of temperature transients resulting from ventilation fan failure under varying outside air conditions. The analysis included the response of the building fire protection system in mitigating the temperature transient. Through utilisation of this model, transient natural convection analysis of several temperature excursions were rapidly developed.

KEYWORDS: rooms, air flow, natural ventilation, computer programs, calculating, nuclear reactors.


File Size : 1 file , 770 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-18039
Published : 1994

History


Related products


Best-Selling Products

CAN/CSA-ISO/IEC ISP 10608-1-99 (R2003)
Published Date: 02/22/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 1: General Overview and Subnetwork- Independent Requirements (Adopted ISO/IEC 10608-1:1992, first edition)
$21.9
CAN/CSA-ISO/IEC ISP 10608-12-99 (2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 12: MAC Sublayer and Physical Layer Dependent Requirements for a CSMA/CD LAN Subnetwork (Adopted ISO/IEC ISP 10608-12:1996)
$15.9
CAN/CSA-ISO/IEC ISP 10608-13-01
Published Date: 03/12/2001
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless-Mode Network Service - Part 13: MAC Sublayer and Physical Layer Dependent Requirements for a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-13:1994, first edition, 1994-0
$15.9
CAN/CSA-ISO/IEC ISP 10608-14-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 14: MAC, PHY and PMD Sublayer Dependent and Station Management Requirements Over an FDDI LAN Subnetwork (Adopted ISO/IEC ISP 10608-14:1995)
$27
CAN/CSA-ISO/IEC ISP 10608-2-99 (R2003)
Published Date: 02/19/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 2: TA51 Profile Including Subnetwork Dependent Requirements for CSMA/CD Local Area Networks (LANs) (Adopted ISO/IEC ISP 10608-2:1992)
$15.9
CAN/CSA-ISO/IEC ISP 10608-4-99 (R2003)
Published Date: 02/18/2000
Information Technology - International Standardized Profile TAnnnn - Connection-Mode Transport Service Over Connectionless- Mode Network Service - Part 4: Definition of Profile TA53, Operation Over a Token Ring LAN Subnetwork (Adopted ISO/IEC ISP 10608-4:1994, first edition)
$14.1