Numerical Investigation of External Convective Heat Transfer Coefficient for Buildings in Different Land Use Class PDF

Numerical Investigation of External Convective Heat Transfer Coefficient for Buildings in Different Land Use Class PDF

Name:
Numerical Investigation of External Convective Heat Transfer Coefficient for Buildings in Different Land Use Class PDF

Published Date:
2020

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Convective heat transfer coefficient (CHTC) is known to play an important role in the evaluation of heat exchange between a building and its surroundings. There are several correlations suggested for the estimation of CHTC from the external surfaces of a building. However, there is a marked difference between values obtained from these correlations under similar set of conditions. Therefore, there is a need for an extensive correlation addressing the discrepancies in some of the existing correlations. In the current study, the impact of built morphology, associated with different land-use classes (e.g., industrial, residential, or downtown, etc.), on the convective heat transfer from buildings is numerically investigated. CFD simulations are conducted in a Navier-Stokes solver with Reynolds stress turbulence model as a closure method. The surrounding buildings are expected to influence the local microclimate (wind speed and turbulence), which in turn will affect the CHTC of the study building. Arrays of building-like bluff bodies from different land-use class with several packing density representing different flow regimes, and a benchmarking isolated cube case, have been investigated. Frontal/planar densities of sections of various parts of cities, based on their land-use class - from literature, are used to relate CHTC findings from simulation to land-use classifications. The results indicate that the behavior of convective heat transfer from building surfaces significantly depends on the land-use class designation of the location of the study building. The development of land-use class based CHTC correlations is expected to reduce the bias resulting from using correlation based exclusively on isolated building studies.
File Size : 1 file , 3.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-BSC20-C025
Published : 2020
Units of Measure : Dual

History


Related products


Best-Selling Products

PDI BPSGI
Published Date:
Basic Principles for Sizing Grease Interceptors
PDI G 101
Published Date: 03/01/2010
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance
PDI G 102
Published Date:
Testing and Certification for Grease Interceptors with FOG Sensing and Alarm Devices
PDI GGI-EM
Published Date: 01/01/2010
Guide To Grease Interceptors: Eliminating the Mystery
PDI MGO
Published Date:
Model Grease Ordinance
PDI MSREPFS
Published Date: 01/01/2009
MINIMUMSPACE REQUIREMENTS FOR ENCLOSED PLUMBING FIXTURE SUPPORTS