NY-08-014 (RP-1292) -- Performance of VAV Series Fan-Powered Terminal Units: Experimental Results and Models PDF

NY-08-014 (RP-1292) -- Performance of VAV Series Fan-Powered Terminal Units: Experimental Results and Models PDF

Name:
NY-08-014 (RP-1292) -- Performance of VAV Series Fan-Powered Terminal Units: Experimental Results and Models PDF

Published Date:
2008

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Empirical models of airflow output and power consumption were developed for series fan powered variable air volume terminal units at typical operating pressures. Terminal units with 8 in. (203 mm) and 12 in. (304 mm) primary air inlets from three different manufacturers were evaluated. Generalized models were developed from the experimental data with coefficients varying by size and manufacturer.

Fan power and airflow data were collected at downstream static pressures of 0.25 w.g. (63 Pa). Upstream static pressures ranged from 0.1 to 2.0 in w.g. (25 to 498 Pa). Data were collected at four different primary air damper positions and at four terminal unit fan speeds. Model variables included the RMS voltage entering the terminal unit fan, the inlet air differential sensor pressure, and the upstream static pressure.

In all but one of the VAV terminal units, the resulting models of airflow and power had R2 values greater than 0.98. For the remaining unit, a faulty motor had been installed and shipped in the unit which prevented proper operation of the SCR. These models can be applied to HVAC simulation programs to model series fan powered VAV systems.

Units: Dual

 


File Size : 1 file , 2.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 7
Product Code(s) : D-NY-08-014
Published : 2008

History


Related products


Best-Selling Products

CI/CHLOR IB/A
Published Date: 05/01/2023
Instruction Booklet: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100-LB. & 150-LB. CHLORINE CYLINDERS
CI/CHLOR IB/A
Published Date: 07/01/2014
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100 LB. & 150 LB. CHLORINE CYLINDERS
CI/CHLOR IB/A
Published Date: 01/01/2021
Instruction Booklet: Chlorine Institute Emergency Kit "A" For 100LB. & 150 LB. Chlorine Cylinders
$12
CI/CHLOR IB/A
Published Date: 01/01/2013
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “A” FOR 100 LB. & 150 LB. CHLORINE CYLINDERS
CI/CHLOR IB/B
Published Date: 12/01/2013
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “B” FOR CHLORINE TON CONTAINERS
CI/CHLOR IB/B
Published Date: 07/01/2014
INSTRUCTION BOOKLET: CHLORINE INSTITUTE EMERGENCY KIT “B” FOR CHLORINE TON CONTAINERS