NY-14-014 -- Theoretical Estimation of the Performance of a Photovoltaic-Thermal Collector (PV/T) System Coupled with a Heat Pump in a Sustainable House in Toronto PDF

NY-14-014 -- Theoretical Estimation of the Performance of a Photovoltaic-Thermal Collector (PV/T) System Coupled with a Heat Pump in a Sustainable House in Toronto PDF

Name:
NY-14-014 -- Theoretical Estimation of the Performance of a Photovoltaic-Thermal Collector (PV/T) System Coupled with a Heat Pump in a Sustainable House in Toronto PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

In this study, an analysis has been conducted to estimate the potential benefits of integratingaphotovoltaic thermal collector (PV/T) with a two-stage variable capacity air-source heat pump (TS-VCASHP) in aToronto and Region ConservationAuthority (TRCA) archetype sustainable house (ASH) in Toronto. A comprehensive analysis has been conducted to predict the effect of PV/T system arrangement configurationNS ×NR (number of PV/T systems in rowsNR and seriesNS), air mass flow rate and duct depth on thermal energy production, electrical energy production, heat-pump coefficient of performance (COP), electricity consumed by the heat pump, and overall PV/T system efficiency. It was found that COP could be increased from 2.74 to a maximum value of 3.45. The results show that the heat pump electricity consumption for heating purpose was reduced by 20.2% with combining PV/T systems with air-source heat pumps. The maximum achieved system efficiencies for the arrangements 5 × 3, 5 × 4, and 5 × 5, with total mass flow rate of 1.2 kg/s (2.64 lb/s)were54%,50%,and47%,respectively.For the same total number of PV/T panels used in one array and same total mass flow rate, it is better to haveNS greater thanNR in order to produce more thermal energy. This consideration has slight effect on the total electricity production. It is found that the amount of electrical energy produced from each PV panel depends on the panel position in a row. The first PV panel has the highest efficiency (14.16%) and produces 763Wh(2603 Btu/ h) of electricity, while the fifth PV panel has the lowest value of efficiency (14.06%) and generates 756Wh (2580 Btu/h) of electricalenergy.


File Size : 1 file , 5.3 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 13
Product Code(s) : D-NY-14-014
Published : 2014

History


Related products


Best-Selling Products

ICEA P-117-734-2016
Published Date: 02/23/2016
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$90
ICEA P-117-734-2022
Published Date: 07/06/2022
Ampacities For Single-Conductor Solid Dielectric Power Cable 15 kV Through 35 kV
$96
ICEA P-123-739-2018
Published Date: 01/18/2018
GUIDE TO ESTABLISH ELECTRICAL TEST METHODS FOR NON-CONDUCTING JACKET MATERIALS FOR POWER CABLES RATED 5 TO 500 KV
$22.5
ICEA P-124-736-2021
Published Date: 06/03/2021
Code Words for 600 Volt Underground Distribution Cables
$13.5
ICEA P-127-737-2021
Published Date: 06/03/2021
Code Words for Overhead Aluminum Covered Conductors and 600 Volt Overhead Cables
$13.5
ICEA P-136-726-2024
Published Date: 2024
Guide for Pellet Inspection Systems for Unfilled Power Cable Insulation Compound
$29.1