NY-14-C071 -- Generation of Multizone Airflow Models from Building Energy Models PDF

NY-14-C071 -- Generation of Multizone Airflow Models from Building Energy Models PDF

Name:
NY-14-C071 -- Generation of Multizone Airflow Models from Building Energy Models PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The creation of building performance simulation models is time consuming and requires a great deal of expertise and building-specific knowledge. The total investment of resources required to construct a model strongly depends upon the size and complexity of the building under consideration, but in general the effort may be thought of as a four-step process: gather the necessary building information, convert this information into the format required by the simulation program, troubleshoot any issues that arise, and simulate the building. If the modeler needs to use more than one simulation program for the analysis process, then it is likely that much of the process must be repeated for each program. Even if no additional data are required (removing the need for the first step), the modeler will likely need to translate this information into a different form for each simulation program and the troubleshooting and simulation steps will require knowledge of the simulation program in use. This paper describes a "single model" approach, in which a more complex EnergyPlus energy model is used to generate a less complex CONTAM airflow model. This reduces the overall effort required to perform both analyses on a single building. The resulting airflow models are fully-functional and are suited for use in parametric simulation studies but by necessity are not as detailed as purpose-built models might be. The procedure uses a base energy model that is constructed with the open-source OpenStudio energy modeling toolset and then translated into a simplified airflow model using the OpenStudio software development kit. An example contaminant transport application, quantification of building security against chemical/biological extreme events, is presented and the advantages and limitations of this approach are discussed, along with possible future applications.


File Size : 1 file , 2.2 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-NY-14-C071
Published : 2014

History


Related products


Best-Selling Products

NEN NEN 1006+A1
Published Date: 06/01/2018
Algemene voorschriften voor leidingwaterinstallaties
$15.9
NEN NEN 1010
Published Date: 01/01/2020
Elektrische installaties voor laagspanning – Nederlandse implementatie van de HD-IEC 60364-reeks
$130.8
NEN NEN 1059
Published Date: 06/01/2019
Nederlandse editie op basis van NEN-EN 12186 en NEN-EN 12279 - Gasvoorzieningsystemen - Gasdrukregel- en meetstations voor transport en distributie
$26.4
NEN NEN 11298-2
Published Date: 10/01/1995
Process measurement and control devices - General methods and procedures for evaluating performance - Part 2: Test under reference conditions
$17.1
NEN NEN 2075
Published Date: 09/01/2018
Quality measuring system and process control system for cleaning performance
$19.8
NEN NEN 2767‐1+C1
Published Date: 05/01/2019
Condition assessment built environment ‐ Part 1: Methodology
$21.3