NY-14-C081 -- In Situ Testing of Earth-Air Heat Exchangers: Under Slab vs. Under Yard PDF

NY-14-C081 -- In Situ Testing of Earth-Air Heat Exchangers: Under Slab vs. Under Yard PDF

Name:
NY-14-C081 -- In Situ Testing of Earth-Air Heat Exchangers: Under Slab vs. Under Yard PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Earth-air heat exchangers (EAHX) have the potential to reduce residential heating and cooling loads by pre-conditioning outside air through under soil pipes. Typical installations of EAHX occur in green space located adjacent to existing residences. However, during new construction these systems could be installed under the foundation with a minimum amount of additional excavation taking place. The following study compares the performance of both installation types located at a residence in Bozeman, Montana. The comparison indicates the soil temperature distribution and heat transfer mechanisms are different for each location. For a comprehensive comparison, the annual soil temperatures under the green space and foundation are modeled using an analytical and finite element method approach respectively. This is done for both a heating and cooling dominate climate. The results indicate the annual soil temperatures in the green space vary around the average annual surface temperature while under the foundation the temperatures are higher and relatively constant. It was concluded that for a heating dominate climate the under foundation installation results in higher annual soil temperatures, and thus greater energy savings through the heating season. Cooling dominated climates tend to benefit more from installations under the green space where soil temperatures are reduced during the winter months.


File Size : 1 file , 1.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-NY-14-C081
Published : 2014

History


Related products


Best-Selling Products

UNE-CLC/TR 50373:2006 IN
Published Date: 06/07/2006
Wind turbines - Electromagnetic compatibility
UNE-CLC/TR 50453:2008 IN
Published Date: 11/26/2008
Evaluation of electromagnetic fields around power transformers
UNE-CLC/TR 50462:2009
Published Date: 10/14/2009
Rules for the determination of uncertainties in the measurement of the losses on power transformer and reactors
UNE-CLC/TR 50488:2007 IN
Published Date: 07/18/2007
Railway applications - Safety measures for the personnel working on or near overhead contact lines