NY-87-14-5 -- Spread of Gas in Buildings Exposed to Poisonous Outdoor Air PDF

NY-87-14-5 -- Spread of Gas in Buildings Exposed to Poisonous Outdoor Air PDF

Name:
NY-87-14-5 -- Spread of Gas in Buildings Exposed to Poisonous Outdoor Air PDF

Published Date:
1987

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Two years ago a study of gas spread from outdoor exposure was carried out for a governmental-level committe dealing with problems related to hospitals in war situations. Among the representative types that were to be studied there were two categories of modern hospital buildings, viz., large and tall buildings and buildings of medium height. The results presented in the paper concern these two types. Questions that were to be answered are:

How does the gas concentration vary in a building when a toxic gas cloud drifts into a hospital area?

How does airtightness of outer walls, roofs and internal partitions affect the gas spread?

How does the height of the building affect the gas spread?

To limit the costs we combined a minimum of experimental testing with calculating a number of cases with varying values of parameters. Calculation was possible thanks to a calculation model by S. Bergström (1985). It was orginally developed to study infiltration and ventilation with respect to energy demand, but can be applied to other problems. One is the problem dealt with in the paper. Another and similar problem is spread of smoke gas in a building when gas is generated somewhere indoors.

Units: SI


File Size : 1 file , 880 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-NY-87-14-5
Published : 1987

History


Related products


Best-Selling Products

UNE-CLC/TS 50131-2-2:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-2: Requirements for passive infrared detectors
UNE-CLC/TS 50131-2-3:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-3: Requirements for microwave detectors
UNE-CLC/TS 50131-2-4:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-4: Requirements for combined passive infrared and microwave detectors
UNE-CLC/TS 50131-2-5:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-5: Requirements for combined passive infrared and ultrasonic detectors
UNE-CLC/TS 50131-2-6:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 2-6: Requirements for opening contacts (magnetic)
UNE-CLC/TS 50131-3:2005 V2
Published Date: 09/14/2005
Alarm systems - Intrusion systems -- Part 3: Control and indicating equipment