NY-91-02-1 -- A Simplified, High-Efficiency DUBLSORB System PDF

NY-91-02-1 -- A Simplified, High-Efficiency DUBLSORB System PDF

Name:
NY-91-02-1 -- A Simplified, High-Efficiency DUBLSORB System PDF

Published Date:
1991

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

DUBLSORB is the name given to the broad class of hybrid absorption and liquid desiccant cycles where heat usually rejected from an absorption chiller to a cooling tower is used to provide at least a portion of the liquid desiccant regeneration heat. The initial development was a basic cycle where heat from the condenser of an absorption chiller drove the desiccant regenerator. With this basic cycle, direct-fired heating of the regenerator was necessary when the latent load was more than 25% of the total cooling load. In other developments reported previously, DUBLSORB systems were defined that could respond efficiently to the load regardless of the ratio of latent load to total load but with increases in the level of system complexity. The new system presented here is the result of evaluating the alternative trade-offs among several of the DUBLSORB concept variations. Compared with other DUBLSORB systems, simplicity is achieved in this new system, solution additives are minimised, spindown to lower concentrations is eased, performance is improved, and any amount of latent load is efficiently handled without an auxiliary burner. A representative seasonal coefficient of performance (COP) of 1.5 is predicted. This system is expected to require little special engineering for each application. Once the design sensible load for a given building is determined, this system is expected to provide adequate latent capability for almost all applications. For minimum first cost, the liquid desiccant dehumidifier would be sized for the latent load, recognising that additional dehumidification capability could be added if the latent load is larger than anticipated. In addition, the system is expected to be quite forgiving under overload conditions in that latent load capability can be maintained, even though sensible load capability is inadequate. This system should provide a major improvement in comfort when contrasted with more conventional systems in which an overload causes loss of control of both sensible and latent loads.

KEYWORDS: absorption refrigeration, desiccants, heat exchangers, dehumidifiers, comparing, performance, coefficient of performance, efficiency


File Size : 1 file , 950 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 7
Product Code(s) : D-18395
Published : 1991

History


Related products


Best-Selling Products

1A1W1S1 Archive Product 105
Published Date: 01/01/2000
Welding Inspection Handbook
1A1W1S1 Archive Product 111
Published Date: 02/01/1981
Welding Technology for the Aerospace Industry
1A1W1S1 Archive Product 115
Published Date: 01/01/2002
Structural Welding Code - Steel
1A1W1S1 Archive Product 138
Published Date: 01/01/2002
Standard Welding Procedure Specification (Swps) for Gas Tungsten Arc Welding of Carbon Steel to Austenitic Stainless Steel (M-1, P-1 or S-1 to M-8, P-8, or S-8), 18 through 10 Gauge, in the As-Welded Condition, with or without Backing
1A1W1S1 Archive Product 142
Published Date: 01/01/2001
Ventilation Guide for Weld Fume
1A1W1S1 Archive Product 167
Published Date: 08/01/2008
Structural Welding Code Steel Bundled Set A