OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

Name:
OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The paper represents the second part of a comprehensive study on modeling heat transfer in metal building roof insulation assemblies containing fiberglass insulation. Part 1 described the development and experimental validation of a comprehensive three-dimensional mathematical model for heat transfer (and air flow where applicable) in metal building roof insulation assemblies. The model was used to calculate U-factors for several standing seam roof (SSR) and throughfastened roof (TFR) assemblies assuming the insulation drapes between the purlins to be parabolic. The second part of the work used the results from the model described in part 1 to develop a relatively simple approach to predict the overall heat transfer coefficient (U-factor) of insulated metal building roof insulation assemblies. It is shown that the U-factors obtained using the numerical model may be correlated, to a fairly high degree (R2 = 0.998), to an overall or system thermal resistance parameter, Rinsul-sys as shown below.

 1/U = 0.8672 Rinsul-sys + 1.132

In the above equation, U is in Btu/ft2·h·°F and R is in ft2·h·°F/Btu. 1 Btu/ft2·h·°F = 5.6782 W/m2·K and 1 ft2·h·°F/Btu = 0.17611 m2·K/W.

The parameter Rinsul-sys is calculated by combining three thermal resistances operating in parallel. Two of these resistances of equal value correspond to the insulation drapes on either side of the purlin and the one in the middle represents the thermal resistance of insulation over the purlin. An analytical expression for the R-value of the parabolic insulation drape is derived. The approach developed in this paper greatly enhances our ability to predict U-factors for metal building roof assemblies.

Units: Dual

 


File Size : 1 file , 690 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-OR-10-018
Published : 2010

History


Related products


Best-Selling Products

VG 95370-10
Published Date: 12/01/1983
Electromagnetic Compatibility; Electromagnetic Compatibility of & in Systems - Test Method for Interference Currents
VG 95374-1
Published Date: 11/01/1992
Electromagnetic Compatibility (EMC) including Electromagnetic Pulse (EMP) and Lightning Protection - Program and Procedures - Administrative Regulations