OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

Name:
OR-10-018 -- ASHRAE Standard 90.1 Metal Building U-Factors-Part 2: A Systems Based Approach for Predicting the Thermal Performance of Single Layer Fiberglass Batt Insulation Assemblies PDF

Published Date:
2010

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The paper represents the second part of a comprehensive study on modeling heat transfer in metal building roof insulation assemblies containing fiberglass insulation. Part 1 described the development and experimental validation of a comprehensive three-dimensional mathematical model for heat transfer (and air flow where applicable) in metal building roof insulation assemblies. The model was used to calculate U-factors for several standing seam roof (SSR) and throughfastened roof (TFR) assemblies assuming the insulation drapes between the purlins to be parabolic. The second part of the work used the results from the model described in part 1 to develop a relatively simple approach to predict the overall heat transfer coefficient (U-factor) of insulated metal building roof insulation assemblies. It is shown that the U-factors obtained using the numerical model may be correlated, to a fairly high degree (R2 = 0.998), to an overall or system thermal resistance parameter, Rinsul-sys as shown below.

 1/U = 0.8672 Rinsul-sys + 1.132

In the above equation, U is in Btu/ft2·h·°F and R is in ft2·h·°F/Btu. 1 Btu/ft2·h·°F = 5.6782 W/m2·K and 1 ft2·h·°F/Btu = 0.17611 m2·K/W.

The parameter Rinsul-sys is calculated by combining three thermal resistances operating in parallel. Two of these resistances of equal value correspond to the insulation drapes on either side of the purlin and the one in the middle represents the thermal resistance of insulation over the purlin. An analytical expression for the R-value of the parabolic insulation drape is derived. The approach developed in this paper greatly enhances our ability to predict U-factors for metal building roof assemblies.

Units: Dual

 


File Size : 1 file , 690 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-OR-10-018
Published : 2010

History


Related products


Best-Selling Products

BS ISO/IEC 10021-1:1990
Published Date: 03/29/1991
Information technology. Text communication. Message-oriented text interchange systems (MOTIS). System and service overview
$119.634
BS ISO/IEC 10021-2:1990
Published Date: 03/29/1991
Information technology. Message handling systems (MHS)-Information technology. Text communication. Message-oriented text interchange systems (MOTIS). Overall architecture
$119.634
BS ISO/IEC 10021-2:1996
Published Date: 01/15/1998
Information technology. Message handling systems (MHS)-Overall architecture
$119.634
BS ISO/IEC 10021-3:1990
Published Date: 03/29/1991
Information technology. Text communication. Message-oriented text interchange systems (MOTIS). Abstract service definition conventions
$92.964
BS ISO/IEC 10021-4:1990
Published Date: 03/29/1991
Information technology. Text communication. Message-oriented text interchange systems (MOTIS). Message transfer system: abstract service definition and procedures
$119.634
BS ISO/IEC 10021-4:1997
Published Date: 01/15/1998
Information technology. Message handling systems (MHS)-Message transfer system. Abstract service definition and procedures
$119.634