OR-20-018 -- Laboratory Performance Measurement of Blowers with Electronically Commutated Motors in Horizontal Low-Profile Fan Coil Units (RP-1741) PDF

OR-20-018 -- Laboratory Performance Measurement of Blowers with Electronically Commutated Motors in Horizontal Low-Profile Fan Coil Units (RP-1741) PDF

Name:
OR-20-018 -- Laboratory Performance Measurement of Blowers with Electronically Commutated Motors in Horizontal Low-Profile Fan Coil Units (RP-1741) PDF

Published Date:
2020

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
The goal of this study was to quantify the efficiency ofblowers driven by electronically commutated motors (ECMs)in horizontal low-profile fan coil units (FCUs) over the typicalrange of operating pressure. The airflow and power of twelveFCUs from three manufactures were measured over an externalstatic pressure (ESP) range from 0 to 125 Pa (0 to 0.5 in.w.g.) in a well-instrumented laboratory environment. The overallefficiency of blower/motor combination was also determinedfrom the experimental measurements. Due to differentECM controls, the effect of increasing ESP on airflow andpower varies among units from different manufactures. Blowerswith constant torque control may suffer from moderate tosignificant airflow decreases while blowers with constantairflow control maintains airflow over the tested ESP range.The overall efficiency increased with increasing ESP althoughdrops in efficiency were measured at the higher end of ESPs atlower speeds. The maximum overall efficiency measured fromthe twelve units was under 25% while 91% of the data pointswere below 20%, which was dramatically lower than thedefault efficiency of 60 to 70% in building energy simulationprograms. Statistical measures of 25% percentile, median, and75% percentile in the overall efficiency over the tested ESPrange were identified through statistical analysis. Theseresults provided important information on the power calculationsof blowers with ECMs in horizontal low-profile fan coilunits with ESPs ranging from 0 to 125 Pa (0 to 0.5 in. w.g.).
File Size : 1 file , 2.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-OR-20-018
Published : 2020
Units of Measure : Dual

History


Related products


Best-Selling Products

ASQ A3534-1-1993
Published Date: 01/01/1993
ANSI/ISO/ASQ Standard - Statistics - Vocabulary and Symbols - Probability and General Statistical Terms (Revision and Redesignation of ANSI/ASQ A1 and A2-1987)
$19.5
ASQ B1-B3-1996
Published Date: 02/26/1996
Guide for Quality Control Charts - Control Chart Method of Analyzing Data - Control Chart Method of Controlling Quality During Production - Includes B1, B2, and B3
$17.7
ASQ C1-1996
Published Date: 01/01/1996
Specifications of General Requirements for a Quality Program - SAME AS ANSI Z1.8-1971
$14.7
ASQ D1160-1995
Published Date: 01/01/1995
Formal Design Review
$14.7