PH-97-08-5 -- Evaluation of Five Simple Ventilation Strategies Suitable for Houses Without Forced-Air Heating PDF

PH-97-08-5 -- Evaluation of Five Simple Ventilation Strategies Suitable for Houses Without Forced-Air Heating PDF

Name:
PH-97-08-5 -- Evaluation of Five Simple Ventilation Strategies Suitable for Houses Without Forced-Air Heating PDF

Published Date:
1997

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Houses without forced-air heating systems may not experience adequate distribution of their outdoor air supply. This project examined five simple ventilation systems suitable for such houses. Four were exhaust-only, using either only local exhaust fans in the kitchen and bathrooms or the local exhaust fans supplemented with a partially distributed exhaust system with pickups in each bedroom. Each approach was tested with deliberate passive inlet vents (both distributed and centralised) both open and closed. The fifth system was a supply and exhaust system with small-sized ducts supplying outdoor air to each room and the local exhaust fans providing the exhaust. The five ventilation systems were installed in a two-storey house that also has an electric forced-air heating system. Using tracer gas techniques, the air distribution patterns provided by each system for a wide range of weather conditions were measured and compared with similar reference measurements in the house with no mechanical air exchange with the outdoors and with only the forced-air furnace fan operating to circulate the air within the house. The local exhaust fan system with no passive inlet vents was found to provide inadequate distribution of the outdoor air supply, only marginally better than simple air leakage alone. With the distributed passive inlet vents open, the local exhaust fan system was found to distribute more outdoor air to the ground-floor rooms than the upper-storey bedrooms. The partially distributed exhaust system was effective at improving the ventilation air distribution to the bedrooms. The minimal ducted supply system provided the best outdoor air distribution to all habitable rooms.

KEYWORDS: year 1997, Calculating, ventilation, housing, air distribution, air change rate, Canada, research, measuring, outdoor air, housing, air quality, indoor, comparing, mechanical ventilation


File Size : 1 file , 1.4 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-16461
Published : 1997

History


Related products


Best-Selling Products

AIHA AEAB06-715
Published Date: 01/01/2006
Essential Air Monitoring Methods (MAK-Collection for Occupational Health and Safety)
$62.4
AIHA AEAG00-382
Published Date: 01/01/2000
Investigations: A Handbook for Prevention Professionals
$31.8
AIHA AEAG07-726
Published Date: 01/01/2007
Guidance for Conducting Control Banding Analyses
$36
AIHA AEAG99-381
Published Date: 01/01/2000
User's Guide to A Strategy for Assessing and Managing Occupational Exposures
AIHA AEAH07-725
Published Date: 01/01/2007
Preventing Hazards at the Source
$36.3
AIHA AEAH10-559
Published Date:
2010 ERPG & WEEL Handbook
$17.4