Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Both vented and unvented designs of catalytic heaters using natural gas and propane as the fuel were tested by three test methods. The objective of the study was to determine an appropriate laboratory test method for determining the percentage of unreacted fuel during typical heater use.

Results of this study are expected to be useful for manufacturers who are currently developing an ANSI standard for catalytic heaters and by the Department of Energy for their Appliance Efficiency Test Procedures. Results showed that an analytical approach of calculating unreacted fuel using a carbon balance was equivalent to an empirical method. Results of tests in two open-room test methods and one closed room test method showed that the methods to use will depend on whether the heater is vented or unrented.

A closed room method was shown to yield results consistent with those obtained by open-room methods for the unvented heater, and may be used in place of an open-room method if the room oxygen is not depleted below 19 % as an end-point of the test. A completely sealed test room was found to be unnecessary for this closed room test.

Units: Dual

 


File Size : 1 file , 2.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 19
Product Code(s) : D-PO-86-06-2
Published : 1986

History