QC-06-019 - Thermal Profile of World’s Third Fastest Supercomputer PDF

QC-06-019 - Thermal Profile of World’s Third Fastest Supercomputer PDF

Name:
QC-06-019 - Thermal Profile of World’s Third Fastest Supercomputer PDF

Published Date:
2006

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper describes the thermal profile of a high-performance computing cluster located in two different data centers with quite different thermal profiles. The high-performance advanced simulation and computing (ASC) cluster, code named ASC Purple, is the world’s third fastest supercomputer (Top 500 Supercomputer Sites, http://www.top500.org/), operating at a peak performance of 77.8 TFlop/s. It contains more than 12,000 processors, 50 terabytes of memory, and 2 petabytes of globally accessible disk space. The cluster was first tested in the manufacturer’s development laboratory in Poughkeepsie, New York, and then shipped to a national laboratory in California, where it was installed to support our national security mission. Detailed measurements were taken in both data centers of electronic equipment power usage, perforated floor tile airflow, cable cutout airflow, computer room air-conditioning (CRAC) airflow, and electronic equipment inlet air temperatures. In addition to these measurements, the physical features of the data center were recorded. Results showed that heat fluxes of 700 W/ft2 (7535 W/m2) could be achieved while still maintaining rack inlet air temperatures within specifications. However, in some areas of the Poughkeepsie data center, there were zones that did exceed the equipment inlet air temperature specifications by a significant amount. These areas will be highlighted and reasons will be given for why these areas failed to meet the criteria. Those areas of the cluster in Poughkeepsie that did not meet the temperature criteria were well within the temperature limits at the California installation. Based on the results from these two data centers, necessary and sufficient criteria are outlined for IT racks to achieve inlet air temperatures that meet the manufacturers’ temperature specifications.


File Size : 1 file , 710 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-28740
Published : 2006

History


Related products


Best-Selling Products

CAN/CSA-CEI/IEC 1000-1-1-97 (R2023)
Published Date: 01/18/2000
Electromagnetic Compatibility (EMC) - Part 1: General - Section 1: Application and Interpretation of Fundamental Definitions and Terms (Adopted CEI/IEC 1000-1-1:1992)
$37.8
CAN/CSA-CEI/IEC 1000-2-1-97 (R2023)
Published Date: 01/18/2000
Electromagnetic Compatibility (EMC) - Part 2: Environment - Section 1: Description of the Environment - Electromagnetic Environment for Low-Frequency Conducted Disturbances and Signalling in Public Power Supply Systems (Adopted CEI/IEC 1000- 2-1:1990) / Compatibilite electromagnetique (CEM) - Partie
$36.3
CAN/CSA-CEI/IEC 1160-96 (R2001)
Published Date: 05/03/2000
Formal Design Review (Adopted CEI/IEC 1160:1992) / Revue de conception formalisee (norme CEI/IEC 1160:1992 adoptee)
$31.5
CAN/CSA-CEI/IEC 1258-98 (R2002)
Published Date: 02/25/2000
Guidelines for the Development and Use of Medical Electrical Equipment Educational Materials (Adopted CEI/IEC 1258:1994, first edition) / Guide pour le developpement et l'utilisation des supports educatifs relatifs aux appareils electromedicaux (norme CEI/IEC 1258:1994 adoptee, premiere edition) **
CAN/CSA-CEI/IEC 1288-1-98 (R2012)
Published Date: 02/16/2000
Cardiac Defibrillators - Cardiac Defibrillators-Monitors - Part 1: Operation (Adopted CEI/IEC 1288-1:1993, first edition) / Defibrillateurs cardiaques - Moniteurs-defibrillateurs cardiaques - Partie 1: Fonctionnement (norme CEI/IEC 1288-1:1993 adoptee, premiere edition)
CAN/CSA-CEI/IEC 1288-2-98 (R2012)
Published Date: 02/16/2000
Cardiac Defibrillators - Cardiac Defibrillators-Monitors - Part 2: Maintenance (Adopted CEI/IEC 1288-2:1993, first edition) / Defibrillateurs cardiaques - Moniteurs-defibrillateurs cardiaques - Partie 2: Maintenance (norme CEI/IEC 1288-2:1993 adoptee, premiere edition)