RP-645 -- Refrigerated Storage Door Air Infiltration Utilizing Infiltration Reduction Techniques PDF

RP-645 -- Refrigerated Storage Door Air Infiltration Utilizing Infiltration Reduction Techniques PDF

Name:
RP-645 -- Refrigerated Storage Door Air Infiltration Utilizing Infiltration Reduction Techniques PDF

Published Date:
1992

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$9.6
Need Help?

It is generally accepted that infiltration reduction devices on cold storage doorways such as strip curtains, air curtains, and vestibules will reduce doorway infiltration, and thereby reduce refrigeration load. To date however, little experimental work has been conducted to quantify the effectiveness of such devices under actual operating conditions. Previous investigations have concentrated on the effectiveness of the devices without doorway traffic. Even with protective devices, infiltration through doorways is still considered one of the single largest contributors to refrigeration load. The infiltration contribution is often considered to account for up to 50% of the total load. Therefore, engineers must accurately estimate the contribution of doorway infiltration in sizing cold storage refrigeration equipment.

The current method for determining doorway infiltration, recommended in the ASHRAE Refrigeration Handbook 1990, is based on applying an effectiveness of a protective device to a calculated heat load for an unprotected door. This research project was undertaken to field test the effectiveness of currently utilized protection devices installed on cold storage doorways under a variety of conditions. This research effort included on-site testing of doorway protective devices both under static (no forklift traffic) and dynamic (with forklift traffic) conditions, and at various temperature and humidity differences. The infiltration protection afforded by the devices was determined by conducting tracer gas decay tests on the cold rooms. The effectiveness of eight different types of protection devices have been characterized. In addition, measurements of air exchange for unprotected doors are presented for comparison to current models.


File Size : 1 file , 1.8 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 98
Product Code(s) : D-RP-645
Published : 1992

History


Related products


Best-Selling Products

NFSI B101.0-2017
Published Date: 01/11/2017
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.0-2021
Published Date: 03/12/2021
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.1-2009
Published Date: 10/13/2009
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.1-2020
Published Date: 2020
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.2-2020
Published Date: 2020
Test Method for Determining the Impact on Wet Coefficients of Friction of Various Chemical or Physical Walkway Surface Cleaners and Treatments on Common Hard-Surface Flooring Materials
$18
NFSI B101.3-2012
Published Date: 01/18/2012
Test Method for Measuring Wet DCOF of Common Hard-Surface Floor Materials
$18