RP-755 -- Determination of Effect of Ceiling Systems and Plenum Sound Power Radiated Through Ceilings by Terminal Units PDF

RP-755 -- Determination of Effect of Ceiling Systems and Plenum Sound Power Radiated Through Ceilings by Terminal Units PDF

Name:
RP-755 -- Determination of Effect of Ceiling Systems and Plenum Sound Power Radiated Through Ceilings by Terminal Units PDF

Published Date:
1997

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$9.6
Need Help?

HVAC sources in ceiling plenums are often major contributors to the noise level in occupied spaces below. Duct work or devices in the plenum, such as Variable Air Volume (VAV) boxes, are typical sources of such noise. The radiated sound passes through the ceiling, often only a few centimeters from the device, and enters the room below. This transmission occurs in addition to sound transmission along ducts and consequent radiation from air supply outlets.

At the beginning of this project the situation with respect to mis problem was as follows:
1. There was no standard test method for rating the ability of ceiling materials to reduce the transmission of sound from HVAC components in plenums.

2. It was known that transmission loss results obtained in reverberation room tests according to ASTM E90 [1] did not apply to this situation because of the close coupling between the source and the ceiling panels and the absence of a diffuse sound field in typical plenums.

3. There was no consistent body of information providing designers with typical sound attenuation values for common ceiling types with typical ventilation openings.

4. ARI standard 885-90 [2] provided a method to calculate the sound levels in a room below a plenum containing a sound source. The standard includes a "Plenum/Ceiling Effect" table for use when predicting sound radiation from VAV terminals installed above some typical ceilings. The information to prepare the standard was provided by a few manufacturers, but it did not form a consistent set based on a standard test procedure or accepted method of measurement.

ASHRAE RP-755 was initiated to investigate the transmission of sound through different ceiling types from different sources with the intent of providing more reliable design information to deal with sound transmission through ceilings close to HVAC devices. The development of the need for this project is discussed further in Section 4.


File Size : 1 file , 12 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 168
Product Code(s) : D-RP-755
Published : 1997

History


Related products


Best-Selling Products

ABMA 10-1989
Published Date: 06/05/1989
Metal Balls
ABMA 11:1990 (R2008)
Published Date: 06/17/1990
Load Ratings and Fatigue Life for Roller Bearings
ABMA 11:2014 (R2020)
Published Date: 2014
Load Ratings and Fatigue Life for Roller Bearings
$16.5
ABMA 12.1:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Metric Design
$16.5
ABMA 12.2:1992 (S2020)
Published Date: 04/06/1992
Instrument Ball Bearings - Inch Design
$16.5
ABMA 13:1987 (S2010)
Published Date: 09/02/1987
Rolling Bearing Vibration and Noise (Methods of Measuring)