RP-834 -- Effect of Proper Design Parameters on Airborne Contamination in Poultry Operations PDF

RP-834 -- Effect of Proper Design Parameters on Airborne Contamination in Poultry Operations PDF

Name:
RP-834 -- Effect of Proper Design Parameters on Airborne Contamination in Poultry Operations PDF

Published Date:
2001

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$9.6
Need Help?

Ventilation characteristics and bioaerosol concentrations were evaluated in four poultry slaughter plants. Supply and exhaust airflow rates for each room were measured along with internal air distribution. Each plant used a negative pressure ventilation system without make-up air systems. The primary exhaust capacity was achieved with large roof-mounted exhaust fans in the defeathering rooms. Total airflow of these fans ranged from 25,400 to 98,800 cmh (14,941 to 58,118 cfm). Airflow in the plants typically moved from areas of low bioaerosol concentrations to areas of high bioaerosol concentrations. Because of the lack of planned intakes, air infiltrated into the building through shackle line openings, shipping dock doors, and other openings in the building envelope. Room air distribution was unplanned and unmanaged.

The objectives of the investigations of four poultry slaughtering plants were to:

1. evaluate the ventilation of the plants for airflow capacity and air distribution,

2. characterize concentrations, size distribution, and sources of major bioaerosols, including total aerobic mesophilie bacteria, psychrotrophic bacteria, and yeasts and molds.

3. identify predominant yeast and molds to the genus level.

4. characterize concentration and sources of minor bioaerosols, including Pseudomonas spp., Listeria monocytogenes, Staphylococcus aureas, spp, Escherichia coli, Salmonella, spp and Lactobacilli.

5. correlate bioaerosol concentrations with ventilation airflow and air distribution.

6. provide recommendations for plant layout and ventilation system design to minimize bioaerosol levels.


File Size : 1 file , 4.7 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 193
Product Code(s) : D-RP-834
Published : 2001

History


Related products


Best-Selling Products

ISO/IEEE 11073-00103:2015
Published Date: 03/01/2015
Health informatics - Personal health device communication - Part 00103: Overview
$75
ISO/IEEE 11073-10101:2020
Published Date: 08/01/2020
Health informatics - Device interoperability - Part 10101: Point-of-care medical device communication - Nomenclature
$83.4
ISO/IEEE 11073-10102:2014
Published Date: 03/01/2014
Health informatics - Point-of-care medical device communication - Part 10102: Nomenclature - Annotated ECG
$75
ISO/IEEE 11073-10103:2014
Published Date: 03/01/2014
Health informatics - Point-of-care medical device communication - Part 10103: Nomenclature - Implantable device, cardiac
$83.4
ISO/IEEE 11073-10201:2020
Published Date: 04/01/2020
Health informatics - Device interoperability - Part 10201: Point-of-care medical device communication - Domain information model
$83.4
ISO/IEEE 11073-10206:2024
Published Date: 07/01/2024
Health informatics - Device interoperability - Part 10206: Personal health device communication - Abstract content information model
$75