SA-12-015 -- (RP-1448) Ventilation Requirements for Refrigerating Machinery Rooms PDF

SA-12-015 -- (RP-1448) Ventilation Requirements for Refrigerating Machinery Rooms PDF

Name:
SA-12-015 -- (RP-1448) Ventilation Requirements for Refrigerating Machinery Rooms PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
ANSI/ASHRAE Standard 15-2010 Section 8.11.5 suppliesa formula to determine the ventilation rate requirement forrefrigerating machinery rooms. The current formula suggeststhat the appropriate ventilation rate to flush a refrigerantduring a leak is proportional to the square root of the mass ofthe refrigerant in the room. A search for the historical roots ofthe basis of this approach indicates that this formula was likelydeveloped before 1930. A more rigorous and scientificallysound approach yields a technically defensible rationale forventilation requirements in refrigeration machinery rooms tomaintain safety. This paper examines recorded accidentscenarios to develop an appropriate leakage scenario and aventilation requirement that takes into account several importantparameters: the mass of the refrigerant, refrigerant properties,the volume of the room, the delay in detection, and therecommended concentration limit suggested for health andsafety purposes. After determining an appropriate, time-varyingemission rate, a mass balance equation is used to determinethe concentration of the refrigerant in the room. The refrigerantconcentration in the room is kept below the recommendedconcentration limit by adjusting the ventilation rate.
File Size : 1 file , 3.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 17
Product Code(s) : D-SA-12-015
Published : 2012

History


Related products


Best-Selling Products

MHI CMAA 70
Published Date: 01/01/2015
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$37.8
MHI CMAA 70
Published Date: 01/01/2020
Specification for Top Running Bridge and Gantry Type Multiple Girder Electric Overhead Traveling Cranes
$45
MHI CMAA 74
Published Date: 01/01/2020
Specifications for Top Running and Under Running Single Girder Electric Traveling Cranes Utilizing Under Running Trolley Hoist
$45
MHI CMAA 74
Published Date: 01/01/2015
Specification for Top Running and Under Running Single Girder Electric Overhead Cranes Utilizing Under Running Trolley Hoist
$37.8
MHI CMAA 78
Published Date: 01/01/2014
Standards and Guidelines for Professional Services Performed On Overhead and Traveling Cranes and Associated Hoisting Equipment (Revised 2015)
$14.4
MHI CMAA 79
Published Date: 01/01/2012
Crane Operator's Manual
$5.4